6 - Maintenance
123
Lubrication After Assembly
After disassembling the pump (diaphragm renewal, etc.), the pump
MUST be lubricated with 200 g grease into each lubrication point.
HARDI pump grease cartridge (400g): HARDI item no. 28164600
Overhaul Kit
Pump model: 364.
Diaphragm pump overhaul kit (valves, seals, diaphragms etc.) can be
ordered. Detect the pump model - the overhaul kit can be ordered by
your local dealer.
Model 364: HARDI item no. 75585900.
Speed Transducer for Pump
The speed transducer, measuring rounds per minute (rpm), is located at
the inner side of the PTO shield. This sensor is an inductive type, which
requires metallic protrusions to pass by it to trigger a signal.
Adjustment
1.
Adjust air gap (A) to 4 mm (+/-0.5 mm). Use a feeler gauge or
similar tool.
2.
After adjustment, turn the pump shaft. Verify air gap variations less
than +/-0.5 mm. Check this at the entire circumference.
3.
Verify transducer function:
•
HC 5500:
Correct fitting is indicated by continuous flashing from
transducer, when the shaft is rotating.
•
HC 6500/ISOBUS VT:
Monitor the menu [4.5.4.9.6 PTO pump frequency].
Slanting Indicator Adjustment
If the position of the pointer on the indicator does not correspond to the
actual boom position, the pointer (A) can be adjusted.
1.
Loosen the small bolt (B) sufficiently to allow the wire (C) to be
adjusted.
2.
Place the pointer (A) in correct position and fasten bolt (B) against
the wire (C) again.
Содержание RANGER PRO VH
Страница 4: ...1 EU Declaration 4 ...
Страница 10: ...Table of Contents 6 ...
Страница 108: ...5 Operation 104 ...
Страница 111: ...6 Maintenance 107 Boom Lubrication Oiling Plan Lubrication Oiling Plan Trailer Paralift ...
Страница 142: ...6 Maintenance 138 ...
Страница 149: ...8 Technical Specifications 145 Pump Specifications Pump Model 364 5 5 Pump Model 364 7 0 Pump Model 364 10 0 ...
Страница 164: ...Index 160 ...
Страница 166: ...HARDI INTERNATIONAL A S Herthadalvej 10 DK 4840 Nørre Alslev DENMARK ...