5 - Operation
66
After use
•
Clean the inside of the TurboFiller with the spray gun (E) to remove
chemical residues.
•
Place the spray gun in its storing position.
•
Put the lid on top of the TurboFiller.
•
Pull the locking lever (A) down to unlock the position of the
TurboFiller.
•
Grab the handle above and pull the TurboFiller upwards.
•
Raise the TurboFiller to the storage position and let go of the
locking lever to lock the position.
Filling liquid chemicals by HARDI® TurboFiller (optional)
1.
Fill the main tank at least 1/3 with water (unless otherwise stated
on the chemical container label).
2.
Turn the handle of the suction SmartValve towards “Suction from
Main tank”. Turn pressure SmartValve towards “TurboFiller”. Adjust
Agitation valve to desired setting.
ATTENTION! For increased suction from the TurboFiller, the
Agitation valve can be kept closed.
3.
Engage the pump and set P.T.O. speed at 540 r.p.m. or 1000 r.p.m.
(depending on pump model).
4.
Open TurboFiller lid. Measure the correct quantity of chemical and
fill it into the hopper.
€
DANGER! Always wear face shield and other appropriate personal safety equipment when filling chemicals.
ATTENTION! The scale in the hopper can only be used if the sprayer is parked on level ground! It is recommended to
use a measuring jug for best accuracy.
5.
Engage the hopper transfer device by opening the TurboFiller
suction valve to transfer chemicals to the main tank. The
TurboFiller suction valve must be open for at least 20 seconds after
the chemical is no longer visible in the hopper in order to
completely empty the transfer hoses into the main tank.
€
DANGER! If the TurboFiller and the transfer hoses are not
completely emptied, there is a risk of chemicals being siphoned
out of the main tank!
6.
If the chemical container is empty, it can be rinsed by the Chemical
Container Cleaning device. Place the container over the multi-hole
nozzle and push the container cleaning lever.
€
DANGER! In order to avoid spray liquid hitting the operator, do
not press the lever unless the multi-hole nozzle is covered by a
container, as spray liquid may otherwise hit the operator!
ATTENTION! The rinsing device uses spray liquid to rinse
concentrated chemicals from containers. Always rinse the chemical containers with clean water several times until
they are clean before disposal.
7.
Flush the TurboFiller with clean water from the Rinse tank by turning suction SmartValve towards “Suction from Rinse
tank”. The TurboFiller suction valve must be open for at least 20 seconds after the rinse water is no longer visible in the
hopper in order to empty the transfer hoses completely into the main tank.
Содержание NAVIGATOR 3000
Страница 2: ......
Страница 4: ......
Страница 10: ...1 Welcome 8 ...
Страница 36: ...3 Description 34 ...
Страница 52: ...4 Sprayer setup 50 ...
Страница 82: ...5 Operation 80 ...
Страница 104: ...7 Fault finding 102 ...
Страница 116: ...8 Technical specifications 114 ...
Страница 121: ......