Manual channel
change
8
74
26
100
12
0
120
91.5
+0.8-0.0
91.5
+0.8-0.0
96
96
①
②
⑤
⑥
⑦
⑪
⑩
⑨
⑧
③
④
Each time the key is pressed, the channel changes, and the measured value (PV) and set
value (SV) of the memory zone for each channel are displayed.
Scan time in initial setting mode (Scan time)
Auto channel
change
8
74
26
100
12
0
120
91.5
+0.8-0.0
91.5
+0.8-0.0
96
96
①
②
⑤
⑥
⑦
⑪
⑩
⑨
⑧
③
④
If the key is pressed for more than 1 second, the channel number is changed automatically.
In this case, the change time is the initial It is determined according to the
setting mode scan time setting value
■
Measured value / Set value display mode
In the measured value (PV) / set value (SV) display mode, it is a screen to check the measured value (PV) and set value
(SV) corresponding to the channel number displayed on the channel (CH) window.
※ The set value (SV) displays the set value that changes according to the rate of change when the set rate limit (Rate) operates.
■
Change channel
■
RUN / STOP
The
8
74
26
100
12
0
120
91.5
+0.8-0.0
91.5
+0.8-0.0
96
96
①
②
⑤
⑥
⑦
⑪
⑩
⑨
⑧
③
④
key is pressed more than 2 seconds in PV/SV mode, it can switch between RUN(operating)/STOP(stop) and
measured value displays STOP when operation is stopped, and displays error message code when an error occurs.
■
Temperature setpoint (SV) setting and display mode
Select the memory zone to set and control the temperature set value (SV).
When power is applied, it becomes “PV/SV display mode”
At this time, set the set value with the
8
74
26
100
12
0
120
91.5
+0.8-0.0
91.5
+0.8-0.0
96
96
①
②
⑤
⑥
⑦
⑪
⑩
⑨
⑧
③
④
key while moving to setting and display item SV (set value) →
ZONE
8
74
26
100
12
0
120
91.5
+0.8-0.0
91.5
+0.8-0.0
96
96
①
②
⑤
⑥
⑦
⑪
⑩
⑨
⑧
③
④
,
8
74
26
100
12
0
120
91.5
+0.8-0.0
91.5
+0.8-0.0
96
96
①
②
⑤
⑥
⑦
⑪
⑩
⑨
⑧
③
④
,
8
74
26
100
12
0
120
91.5
+0.8-0.0
91.5
+0.8-0.0
96
96
①
②
⑤
⑥
⑦
⑪
⑩
⑨
⑧
③
④
by pressing the key.
•Initial value : 1
•Setting range : 1~8 Memory Zone
•Select the memory zone to be controlled.
Up to 8 memory zones (storage areas) can store the settings for each channel.
Since the setting values of 8 channels can be saved, in case of 8 channels,
8 channels × 8 memory zones = 64 set values (SV) can be saved.
█
Temperature setpoint setting (SV)
█
Memory Zone Selection (ZONE)
•Initial value: EU 0 % (minimum value of range)
•Setting range: within the input range.
•Set the temperature set value (SV).
You can set up to 8 temperature setpoints from 1 to 8 channels.
Can set set the temperature setpoint to the same value from channel
1 to channel 8 at the same time.
①
②
⑤
⑥
⑦
⑪
⑩
⑨
⑧
③
④
①
②
⑤
⑥
⑦
⑪
⑩
⑨
⑧
③
④