3.1
P
lann
er
3.1
P
lann
er
①
ALL DELETE
Delete all information of designed data and scanned
holes for blasting.
②
HOLE DELETE
Delete hole information only leaving designed data for
blasting.
①
MAXIMUM DELAY TIME
Set the maximum delay time of a detonator (Refer to
HiTRONIC Detonator TDS).
②
MAXIMUM TIME GAP
Set the maximum time gap to design.
③
AUTOMATIC GLOBAL TIME
If the automatic global time is ON, operate the global
detonator time with the time added by the automatic
global time gap to the delay time to fire for the last time.
④
AUTOMATIC GLOBAL TIME GAP
Set the global time gap to be accumulated automatically.
⑤
MANUAL GLOBAL TIME
If the automatic global time is OFF, operate the manual
global time for the global time
⑥
TIME OVERLAP WARNING
If the time is designed within 'Maximum Overlap Time"
set previously by each detonator, warning shall be
displayed.
⑦
MAXIMUM OVERLAP TIME
Set the standard time gap to display
‘
TIME OVERLAP
WARNING'.
①
SOUND FEEDBACK
Available to ON/OFF the sound feedback.
②
SOUND FEEDBACK TYPE
Select whether to make a beep sound or a voice at scanning.
③
MULTIPLE FEEDBACK
Available to make different sounds by 5 multiples.
④
VIBRATION FEEDBACK
Available to generate vibration to receive the feedback even under
noisy environment.
①
NEW ID
If a NEW ID is ON, set to HiTRONIC-II ID (8 digits). If a NEW ID
is OFF, set to HiTRONIC-I ID (6 digits)