117
4. Lost Password
Request A/S
5. Unable to Recharge
①
Upside down USB-C cable to reconnect.
②
Check if USB-C port or cable is damaged.
③
Try with other charger.
6. Short on Detonator Lead, Harness Wire, Main Bus Sheath
◦
Symptom
Unable to communicate at the Blaster if sheath of two wires are
peeled off for short circuit.
◦
Resolution
A) Check the sheath of main bus.
B) Check harness wire. The fixed knot of sheath may be peeled off or the
end of sheath may be peeled off to contact.
C) To find the short circuit, cut wires in sequence from 1/2 of connected
harness wire to check (This method is faster in average than the
consecutive checking method).
7. Defective Contact of Wires (Harness Wire, Blast Main Bus)
◦
Symptom
In case of short circuit in harness wire or blast main bus, a
message of
‘
DISCONNECTED
’
is displayed.
◦
Resolution
A) Check if the wire is well connected to the binding post of Blaster.
B) Check the connection of harness wire and blast main bus. If there is no
problem, check if the wire is cut off in the middle.
2. Disabled Wireless Communication
①
Change a device to wireless channel among paired devices, change ID or device
mode (Remote, Blaster, Repeater): Pairing should be done again due to the
initialization of pairing information.
②
On the inspection screen for remote blast network, it displays
‘‘
xx blaster is not
ready to blast
’
: After the download of detonator information to the blaster,
‘
Select
Blast Mode
’
must be selected for a wireless blast.
③
‘
Unable to communicate with xx device
’
is displayed :
A) Check battery condition.
B) Check antenna connection.
C) Check blast standby condition.
D)
On and Off Communication.
E) Check antenna condition.
F) Change to wireless channel at the Remote and try pairing again.
④
③
and
④
in common :
A) Check if Line of Sight is secured.
B) Move to a place to secure LoS if not secured.
C) Review the use of Repeater if LoS cannot be secured.
3. Unable to communicate with detonator at the blaster
①
Check harness wire: Implement the measurement of resistance.
②
Check Binding Post: Check if mud or foreign substance is trapped.
③
Check if download data is equivalent to currently communicating detonator.
Electronic Blasting System
4.
Maintenance
Electronic Blasting System
4.
Maintenance
4.
2
P
ro
ble
m S
olv
in
g a
t B
las
te
r W
ork
116
4.
2
P
ro
ble
m S
olv
in
g a
t B
las
te
r W
ork
Содержание HEBS II
Страница 1: ...HEBS User Guide Electronic Blasting System...