Individual Interval
If pressing the blast button once, blasters in
the group shall fire automatically in each set
interval. The interval set in each item is the
standby time until the blast of device after the
blast of corresponding device.
In a Individual Interval Mode, it is available to
set the delay time in the blaster until the blast
of the next blaster. If pressing Modify Interval, it
is equally available to set the time.
▶
Simultaneously
If pressing the blast button once, all blasters
in the group shall proceed with the blast
simultaneously.
▶
Synchronized
If pressing the blast button, blasters in the group
shall blast in series. Lagging time between the
last detonator and the previous detonator of the
previous blaster shall be applied.
For example, if lagging time of the last detonator
of the previous blaster is 1300ms and that of the
previous detonator 1275ms, the next detonator
shall begin 25ms post blast after the last
detonator of previous blaster is fired.
▶
Regular Interval
In a regular interval mode, Modify Group
Interval button shall be displayed. If pressing
the corresponding button, it is available to set
Regular Interval.
If pressing the blast button once, blasters in the
group shall proceed with the blast in a regular
interval. If the interval is set as 1,000ms, each
blaster shall carry out the blast in an interval of
1,000ms.
3.3.4
Blast Configuration Setting
2)
Remote
- (c)
Blast Group Setting
3.3.4
Blast Configuration Setting
2)
Remote
- (c)
Blast Group Setting