113
8. Logging fails
◦
Symptom
Not able to receive logging data during logging.
◦
Resolution
A) Check if Planner is connected to Logger.
B) If it is not connected to Logger, reconnect.
C) If the connection is normal, reboot the Logger.
D) Reconnect the Logger.
E) Check Logging.
F) If several trials are implemented for A) to E) processes but the logging fails, contact with A/S in charge.
9. Short of detonator lead, harness wire, and bus bar sheath at charging gun powder
◦
Symptom
Not able to communicate at the Planner if sheath of two wires is peeled off to result in short circuit.
◦
Resolution
A) Must check harness wire. Sheath may be peeled off at the part of knot for fixation, and the end of sheath may be
peeled off to contact.
B) To find the short circuit, cut wires in sequence from 1/2 of connected harness wire to check (This method is faster in
average than the consecutive checking method).
5. Keypad Operation Error
◦
Symptom
Keypad is not operated.
◦
Resolution
A) Press the power button for long 5 seconds for rebooting.
B) If the problem is not resolved even after rebooting, contact with A/S in charge.
6. Date Transmission Error
◦
Symptom
Tried to download at the Planner but failed with a warning sound.
◦
Resolution
A) Reboot Planner and Blaster.
B) Retry the download at the Planner.
C) If several trials are implemented for A) to B) processes but failed to download, contact with A/S in charge.
7. Disconnection between Logger and Planner
◦
Symptom
Connection is cut off between Logger and Planner during the work.
◦
Resolution
A) Reboot Logger.
B) Try to connect Logger at the Planner.
C) If several trials are implemented for A) to B) processes but failed to download, contact with A/S in charge.
Electronic Blasting System
4.
Maintenance
Electronic Blasting System
4.
Maintenance
4.1
P
ro
ble
m S
olv
in
g a
t P
lan
ne
r W
ork
112
4.1
P
ro
ble
m S
olv
in
g a
t P
lan
ne
r W
ork
Содержание HEBS II