background image

105

   

Proceed with recharging to check the 

connection of detonator connected to the 
blaster.

Available to check the remaining time and 
communication result during recharging.

   

In case of detecting a detonator with 

defective connection, touch the "Back" 
button to stop the blasting, or touch "Next" 
to continue.
Available to stop the blast preparation or to 
proceed continuously.

  

Available to check the condition after the 

communication with every electronic detonator and 
to enter the charging step for blasting.

  

Step to check the proceeding of recharging 

for actual firing.

  

Input password.

  Electronic Blasting System

3. 

Menu Configuration

  Electronic Blasting System

3. 

Menu Configuration

3.

3

  B

la

ste

r

3.

3

  B

la

ste

r

104

3.3.5

 

Start Blasting

3) 

Remote

3.3.5

 

Start Blasting

3) 

Remote

Содержание HEBS II

Страница 1: ...HEBS User Guide Electronic Blasting System...

Страница 2: ...Data transmission 63 3 1 7 Others 65 3 2 Logger 3 2 1 Main Menu 70 3 2 2 DET ID Check 70 3 2 3 Line Test 71 3 2 4 Information 73 3 3 Blaster 3 3 1 Intro 74 3 3 2 Main Screen 74 3 3 3 Setting 75 3 3 4...

Страница 3: ...ion of the software provided by Hanwha or leakage of the software through unofficial channels violates Hanwha s software license rights These radio equipments may be radio interference during operatio...

Страница 4: ...erface Connector Blutooth Status LED Planner Connector Charging Port USB C type Buttons Back Up Down OK Display Power Button Tagging Connector Power LED Binding Post Hand Strap Holder Electronic Blast...

Страница 5: ...tton Touch Screen Tripod Connector Belt Strap Holder Antenna Charging Port USB C type Electronic Blasting System 1 Before Use 10 1 3 3 Blaster 2 How to Use Devices 2 How to Use Devices 2 1 Scanning Ty...

Страница 6: ...Communication As shown in the figure connect one end of harness wire to a positive terminal of Logger Connect Logger on the Planner screen Refer to 3 1 5 1 Logger Information Running the Line Test at...

Страница 7: ...e and checking the entering of the next ID the next detonator must be connected In an open air although it will not happen there is a possibility of an error if they are connected almost at the same t...

Страница 8: ...nection of detonator through COMMUNICATION at the Planner after the completion of scanning Refer to 3 1 5 3 Communication Equivalent to 2 Wiring of 2 2 Logging Type Couple the Logger with the Planner...

Страница 9: ...Blasting Transmit detonator s data from Planner to Blaster Maintain the blaster in blaster mode as standby Proceed with the blasting at Remote Refer to 3 3 5 Start Blasting Refer to 2 1 2 3 for charg...

Страница 10: ...mainmenu Touchtostarta newblasting Electronic Blasting System 3 Menu Configuration 3 Menu Configuration 3 1 Planner 3 2 Logger 3 3 Blaster 3 3 1 Planner Menu Configuration 3 1 Planner 3 1 1 Starting S...

Страница 11: ...rag tochange thesequence ADD Touch the button at the bottom to add a new section EDIT Click button Button on the section to edit As shown in the figure if a section information window is displayed edi...

Страница 12: ...PLATE at the bottom to reflect the previously set information DELETE Click button of the group item to delete and click button If the information is displayed click button GROUP MOVE To change the seq...

Страница 13: ...the symbol color FONT COLOR Available to change the font color of a symbol TEMPLATE There are tunnel group user definition TAPs Select desired TAP to change at once to a group information set previou...

Страница 14: ...ow that binds two rows into one For the binding row the delay time is designed by a type to fire two rows in turn If using the binding it is possible to design to fire left side and right side in turn...

Страница 15: ...ttom of screen to display a window to move as shown in the figure At this time add or delete a group with button SCAN Aim to hit the red point on QR code of a detonator Click SCAN button to hear beep...

Страница 16: ...dow at the bottom Drag the slide button Blue Circle from page 19 toward the GROUP DELETE on the right to move Click to delete the group immediately if there is no ID in the group or to display DELETE...

Страница 17: ...display ID on the list Caution Search ID only at the list of selected block To search every ID make sure to set entire section entire group and entire row to search SELECT Click Select the First butto...

Страница 18: ...can ID at the location to insert Select the corresponding deck to scan ID to insert again On the Deck Insert window select whether to insert before or after to insert at the corresponding location EDI...

Страница 19: ...1000 to record 100 time gap DETONATOR ID MANUAL INPUT Click the ID Input window grey bar at the center screen to display keyboard At this time available to input detonator ID directly FLAG SETTING If...

Страница 20: ...t After editing desired value click one item by another item of detonator desired to change for direct reflection After editing click the button for EDIT button to disappear DETONATOR INFORMATION EDIT...

Страница 21: ...g CSV file in the path below Path inside PC TC56 the share save space HiPlanner save IMPORT DESIGN FILE Press SAVE file inside STORAGE Press the corresponding CSV type file to proceed with OPEN Electr...

Страница 22: ...able to input ID directly DECK LOCKING Available to lock deck if the charging of explosives would not be done by following reasons Collapsed hole No detonator No hole No communication Others Available...

Страница 23: ...r to insert before or after in reference to the selected item and input tag number and delay time FLAG SETTING Set flag to search specific ID onsite Scan ID with a scanner to find flag ID equivalent t...

Страница 24: ...to display the mode selection for basic outdoor tunnel and software as shown in the figure Basic mode is equivalent to 3 1 3 Basic Mode STARTNEWBLASTING Electronic Blasting System 3 Menu Configuratio...

Страница 25: ...the sequence of blasting by the first hole of each group When the relay mode is ON the first hole of the next group shall be fired after the first of the previous group In case of OFF after delaying...

Страница 26: ...p Mode After checking if set information is correct set whether to add a section or to create a new section Section Add Add one more section to the present blast pattern to create Creation Delete data...

Страница 27: ...is the time gap to pass to the next external group More than two expanded groups are the time gap to pass from the first expanded row to the second row Hole Time Gap Input the hole time gap in the gr...

Страница 28: ...by the same method as the expanded group information Check the information of blast pattern created in the tunnel mode 3 1 3 3 a Save CSV file in the Planner as in the step Before Starting Then selec...

Страница 29: ...Short Circuit Leakage Resistance 1 K 200 Wiring Track Current 40 mA Electronic Blasting System 3 Menu Configuration Electronic Blasting System 3 Menu Configuration 58 3 1 5 Communication 2 Line Test...

Страница 30: ...logging and tagging POLLING TEST Continuously check abnormal condition of every detonator until the user stops Electronic Blasting System 3 Menu Configuration Electronic Blasting System 3 Menu Configu...

Страница 31: ...device for immediate download TRANSMISSION BY BUTTON CLICK Click the button of a device to transmit among blasters to transmit data Except must save the device to transmit through device search DATA C...

Страница 32: ...f broken Planner during working mount SD card to the spare Planner to import the information from HISTORY or SAVE DATA Automatically save the information of currently working HISTORY Automatically sav...

Страница 33: ...te a new folder Electronic Blasting System 3 Menu Configuration Electronic Blasting System 3 Menu Configuration 66 3 1 Planner 3 1 Planner Cancel Cancel selection Copy Available to copy selected item...

Страница 34: ...ated automatically MANUAL GLOBAL TIME If the automatic global time is OFF operate the manual global time for the global time TIME OVERLAP WARNING If the time is designed within Maximum Overlap Time se...

Страница 35: ...ation Check model name of Logger versions of hardware and software serial number name of Bluetooth device Check the current leakage current and resistance of connected wire Available to select each me...

Страница 36: ...rent value by A unit MODEL Model Name H W Hardware version of corresponding logger S W Software version of corresponding logger S N Serial number of corresponding logger BT Name of Bluetooth device ME...

Страница 37: ...ding blaster on the screen center Check the time and remained battery of the system on the screen top Setting Select the time language and motion mode of blaster Setting of blast configuration Select...

Страница 38: ...elect total 5 languages of Korean English Indonesian Spanish and Japanese Set the system date of corresponding blaster Settheconfigurationofblast changethepasswordusedtostartfiring Input previous pass...

Страница 39: ...ransmit the signal requested for the registration of corresponding device to the remote Check the registration signal at the remote and input the code number on the right to the remote within 30 secon...

Страница 40: ...egistration information to be deleted Input password Connect all blasters and repeater used for wireless blast at the remote Input registered code displayed on the right screen of Blaster Repeater for...

Страница 41: ...the Area shall have the path to deliver the same signal The numeral after the Area number is the Depth which means the step to deliver the signal at the remote If the repeater 02 is moved under the r...

Страница 42: ...each blast mode The item registered in the move list shall be displayed in a box with blue check symbol If Enqueue to Move List is tapped by selecting one by one it is available to register several de...

Страница 43: ...ding blast group shall be inactivated which shall skip being treated as if there is no corresponding group and blaster Move Group shall move the group location Change Blast Mode Electronic Blasting Sy...

Страница 44: ...blast button blasters in the group shall blast in series Lagging time between the last detonator and the previous detonator of the previous blaster shall be applied For example if lagging time of the...

Страница 45: ...fter this Group shall be selected to move the corresponding group to the next group The sequences of group and blasters in the group shall be the sequence of blast Therefore the sequence of blasters i...

Страница 46: ...5 Start Blasting 1 Blaster 3 3 5 Start Blasting 1 Blaster To proceed with the blast touch the Start Blasting on the screen Available to retrieve the previous data for detonator ended without the proc...

Страница 47: ...u Configuration Electronic Blasting System 3 Menu Configuration 3 3 Blaster 3 3 Blaster 94 3 3 5 Start Blasting 1 Blaster Tap the List Button and confirm the list downloaded If any of the downloaded d...

Страница 48: ...ster shall be maintained for a blast standby mode The screen of a blaster shall be converted by carrying out the preparation for the blast at the remote Electronic Blasting System 3 Menu Configuration...

Страница 49: ...isplayed It is available to check the information about corresponding detonator immediately Touch Start standalone blast on the screen Proceed with the communication with a detonator connected to a bl...

Страница 50: ...arging Continuous communication is being carried out If an error occurs the count of detonator with error shall be displayed as NG Charge energy in the electronic detonator for firing Electronic Blast...

Страница 51: ...eater carry out the procedure for the blast at remote A blasting network shall be checked for the corresponding remote Check the connection In case of the above screen touch RETRY after checking the p...

Страница 52: ...ch Next to continue Available to stop the blast preparation or to proceed continuously Available to check the condition after the communication with every electronic detonator and to enter the chargin...

Страница 53: ...ing An additional process is carried out to allow and timing of the blasting of each transmitter The time required for this process depends on the breakaway network configuration If pressing ARM and F...

Страница 54: ...he blasters will automatically fire to match the set blasting mode After entering the ARM phase touch the Back button to send a discharge command to all the blasters Each blaster that carries out the...

Страница 55: ...er rebooting contact with A S in charge 4 Declined App Performance Symptom Either program speed apparently slows down or scan speed slows down Resolution A Press the power button for longer than 5 sec...

Страница 56: ...s method is faster in average than the consecutive checking method 5 Keypad Operation Error Symptom Keypad is not operated Resolution A Press the power button for long 5 seconds for rebooting B If the...

Страница 57: ...tonator occurs after wiring Symptom More than one shot have been detected in Global Detonator Search after the end of communication with Tester or Blaster Resolution A One shot has been detected Find...

Страница 58: ...mmunication Change a device to wireless channel among paired devices change ID or device mode Remote Blaster Repeater Pairing should be done again due to the initialization of pairing information On t...

Страница 59: ...r to try the blast again If ID is unknown input temporary ID and delay time 0ms in the Logger to try the blast again At this time entered arbitrary ID is displayed as NC and one shot of global detonat...

Страница 60: ...onator Damage on the capacitor Symptom Damage on the power capacitor A Possible misfire if the detonator is recovered to try firing again the charging voltage is not sufficient which prevents motion o...

Страница 61: ...al Data Sheet 5 1 HEBS II Technical Data Sheet Explanation Features Normal firing even in short circuit of main bus after blast order Available to input delay time desired by user Fired in an exact ti...

Страница 62: ...onators 5 km Line of Sight 2 000 m 1 45 kg 20 to 60 30 to 60 0 to 45 7 000mAh 12 6V Rechargeable IP65 Material Dimension Contact Hanwha s technical representatives for custom made lengths Need to cons...

Страница 63: ...acity Weight Operating Temperature Storage Transport Temperature Charge Temperature Battery Electrostatic Discharge Resistance Drop Sealing 155 x 75 5 x 18 6 mm 1 000 per Planner 249 g 20 to 50 40 to...

Страница 64: ...61 4 1677 0529 E mail australia hanwha com HMS LATIN AMERICA Hanwha Mining Services Chile Alonso de Cordova 5870 O ce 707 Las Condes Santiago Chile TEL 56 2 2993 7542 E mail hmschile hanwha com HMS IN...

Страница 65: ...Hanwha Corporation Explosives Hanwha Building 17th floor 86 Cheonggyecheon ro Jung gu Seoul Korea 04541 TEL 02 729 1211 FAX 02 729 1850 E mail commercial hanwha com...

Отзывы: