Hampton®H15E-11DirectVentFreestandingGasStove
| 31
installation
Basic
Horizontal Kit
1
90
o
Elbow
1 WallThimbleCover
1 Horiz.Sq.Term.Cap
DURA-VENT TERMINATION KIT
Planning Your Dura-Vent
Installation
TherearetwobasictypesofDura-VentDirectVent
Systeminstallations:horizontalterminationandver-
ticaltermination.Confirmthemaximumhorizontal
runandmaximumverticalrisefromthediagrams
inthe"RigidPipeVentingSystems"section.
Whenplanningyourinstallation,itwillbenecessary
to select the proper length of vent pipe for your
particularrequirements.Forhorizontalinstallations,
determinetheminimumclearancefromtherearof
theunittothewall.Itisalsoimportanttonotethe
wallthickness.(Thewallthimbleissuitablefor2
x4or2x6wallconstruction.)Selecttheamount
ofverticalrisedesiredfor"vertical-to-horizontal"
typeinstallations.
Warning: Always maintain required
clearances (air spaces) to nearby
combustibles to prevent a fire hazard.
Do not fill air spaces with insulation.
Theminimumclearancerequirementsbetweenthe
outerwalloftheventpipeandnearbycombustible
surfacesis1-1/4inch.Besuretocheckthevent
termination clearance requirements from decks,
windows,soffits,gasregulators,airsupplyinlets
andpublicwalkwaysasspecifiedinthe"Exterior
VentTerminalLocations"sectionandinyourlocal
buildingcodes.
Todeterminethelengthofventpiperequiredfor
verticalinstallations,measurethedistancefromthe
unitflueoutlettotheceiling,theceilingthickness,
theverticalriseinanatticorsecondstorey,and
allowforsufficientverticalheightabovetheroofline.
Formulti-storeyapplications,firestopsarerequired
ateachfloorlevel.Ifanoffsetisneeded,additional
pipe,elbowsandsupportswillberequired.
Donotexceedthemaximumnumberofelbows.
One 90
o
for horizontal terminations and two 45
o
forverticaltermination.
AstroCap
Part#946-523/P
Alternate Horizontal
Termination Caps
Alternate
Horizontal
Riser Vent
Terminal
Part# 640-530/P
The FPI AstroCap
TM
is certified for installations using FPI venting
systemsaswellasSimpsonDura-Vent®andDirectVent.
TheFPIAstroCap
TM
isaproprietarytrademarkofFPIFireplaceProd-
uctsInternationalLtd.
Dura-Vent®andDirectVentareregisteredand/orproprietarytrademarks
ofSimpsonDura-VentCo.Inc.