Hampton®H15E-11DirectVentFreestandingGasStove
installation
H1
H
V
Horizontal Venting with Two (2) 90
o
Elbows
Option V
H + H1
A)
1'Min. 3'Max.
B)
2'Min. 4'Max.
C)
3'Min. 5'Max.
D)
4'Min. 6'Max.
E)
5'Min. 7'Max.
F)
6'Min. 8'Max.
Horizontal Venting with Two (2) 90
o
Elbows
Option H
V
H + H1
A)
1'Max. 1'Min. 3'Max.
B)
2'Max. 2'Min. 5'Max.
C)
3'Max. 4'Min. 6'Max.
D)
4'Max. 6'Min. 7'Max.
E)
5'Max. 8'Min. 8'Max.
With these options, max.
totalpipelengthis30feet
with min. of 8 feet total
vertical and max. 8 feet
totalhorizontal.
Please note min. 1 foot
between 90
o
elbows is
required.
With these options, maxi-
mumtotalpipelengthis30
feetwithminimumof6feet
totalverticalandmaximum
8feettotalhorizontal.
Please note minimum 1
foot between 90
o
elbows
is required.
One 90
o
elbow = Two 45
o
elbows.
One 90
o
elbow = Two 45
o
elbows.
H
H1
V
VentrestrictorpositionA(fullyopen),refertothe"Vent
RestrictorPostion"section.
VentrestrictorpositionA(fullyopen),refertothe"Vent
RestrictorPostion"section.
Lengthsdonotincludeelbowindicated
Lengthsdonotincludeelbowindicated