HAMPTON BAY H15E-NG11 Скачать руководство пользователя страница 1

MODELS:      H15E-NG11 Natural Gas       H15E-LP11 Propane   

H15 Direct Vent Gas Fireplace

Owners & 

Installation Manual

www.hampton-fire.com

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.  6988 Venture St., Delta, BC  Canada, V4G 1H4

919-880e

01.12.21

 

-  Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other 

appliance. 

- WHAT TO DO IF YOU SMELL GAS
 • 

Do not try to light any appliance.

 

•  Do not touch any electrical switch: do not use any phone in your building.

 

  Leave the building immediately.

 

•  Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's  

instructions.

 

• If you cannot reach your gas supplier, call the fire department.

 

 

  Installation and service must be performed by a qualified installer, service agency or the gas supplier.

     WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious
injury, death, or property damage. 

Installer: Pleasecompletethedetailsonthebackcover
andleavethismanualwiththehomeowner.
Homeowner: Pleasekeeptheseinstructionsforfuturereference.

Certifiedto/Certifiépour:CSA2.17-2017
ANSIZ21.88-2017
CSA2.33-2017

Testedby:

Содержание H15E-NG11

Страница 1: ...ng Leave the building immediately Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Inst...

Страница 2: ...nuous full seven days of inactivity This only applies if the CPI continuous pilot switch is in the on position in your remote control transmitter Each time the main burner shuts down manually or throu...

Страница 3: ...ns 8 Mobile Manufactured Homes After First Sale 8 Before You Start 8 Lighting Procedure 9 Copy of the Lighting Plate Instructions 10 Proflame II remote control operating Instructions 11 Dura Vent Term...

Страница 4: ...RIZONTAL VENT 22 7 8 19 3 8 24 11 16 20 11 16 17 13 16 19 1 8 14 1 4 13 5 8 21 1 4 19 1 8 525mm 451mm 485mm 540mm 626mm 581mm 492mm 345mm 485mm 361mm ALL PICTURES DIAGRAMS SHOWN THROUGHOUT THIS MANUAL...

Страница 5: ...Hampton H15E 11 Direct Vent Freestanding Gas Stove 5 dimensions UNIT DIMENSIONS WITH VERTICAL VENT...

Страница 6: ...bited by local codes See owner s manual for details Optional Fan Kit Part 382 917 Installer l appareil selon les codes ou r glements locaux ou en l absence de tels r glements selon les codes d install...

Страница 7: ...above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in s...

Страница 8: ...ds to make you aware of the following CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE INSTALLATION AND REPAIR SHOULD BE DONE BY AN AUTHORIZED SERVICE PERSON THE APPL...

Страница 9: ...ystem will need to be reset as follows a Wait 5 minutes turn the system off by pressing the ON OFF button on the remote b After approximately 2 seconds turn on ON OFF switch or press ON OFF button if...

Страница 10: ...cet appareil s il a t plong dans l eau m me partiellement Faites inspecter l appareil par un technicien qualifi et remplacez tout l ment du syst me de contr le ou de commande qui a t plong dans l eau...

Страница 11: ...simple button layout and informative LCD display Fig 1 A Mode Key is provided to index between the features and a Thermostat Key is used to turn on off or index through Thermostat functions Fig 1 2 Ad...

Страница 12: ...height by one step until the flame is turned off The Up Arrow Key will increase the flame height each time it is pressed If the Up Arrow Key is pressed while the system is on but the flame is off the...

Страница 13: ...oflame system The fan speed can be adjustedthroughsix 6 speeds ToactivatethisfunctionusetheModeKey fig 1 to index to the fan control icon Fig 13 Use the Up Down Arrow Keys fig 1 to turn on off or adju...

Страница 14: ...the fireplace is easily changed from an intermittent pilot ignition system IPI to a continuous pilot ignition system CPI by using remote control as noted above The benefits of having as CPI are as fo...

Страница 15: ...bedding material etc It is imperative that control compartments and circulating air passageways of the appliance be kept clean and free from excessive lint from carpeting 4 See general construction a...

Страница 16: ...of the figures but the connector is too close move the stove until the correct clearance to the connector is obtained This appliance may be installed only with the clearances as shown in the situation...

Страница 17: ...the legs as shown On either side of the unit there will be slits located on the body of the stove Slide the fan up into the slits until the mounting holes line up with the holes locatedonthefanassemb...

Страница 18: ...tem perature 2 Lift off cast top and place on a soft surface 4 Slide the light assembly bracket out of the way 5 Lift both latches securing glass door and re move door 6 To reinstall reverse steps 3...

Страница 19: ...s products of combustion to the outside while the outer pipe draws outside combustion air into the combustion chambertherebyeliminatingtheneedtouseheated room air for combustion and losing warm room a...

Страница 20: ...f center line extended above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air in...

Страница 21: ...Black N A N A N A 4DALB N A TC 4DLTB N A Adjustable Length 7 Galvanized N A N A 4D7A N A N A N A N A Adjustable Length 7 Black N A N A 4D7AB N A N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A...

Страница 22: ...for AstroCap 946 205 Vinyl Siding Shield for Riser Vent Terminal 510 994 Rigid Pipe Adaptor Must use with all rigid piping 946 208 P Vent Guard Optional for Riser Vent Terminal 640 530 P Riser Vent Te...

Страница 23: ...t Vent SelkirkDirect Temp AmeriVent Direct venting and Security Secure Vent systems Use of these systems with the Rigid Pipe adaptor is deemed acceptable and does not affect the Intertek WHI listing o...

Страница 24: ...t with min of 8 feet total vertical and max 8 feet total horizontal Please note min 1 foot between 90o elbows is required With these options maxi mum total pipe length is 30 feet with minimum of 6 fee...

Страница 25: ...Max 4 Min D 5 Max 5 Min E 6 Max 6 Min Lengths do not include elbow indicated Vent restrictor position A fully open refer to the Vent Restrictor Position section One 90o elbow Two 45o elbow Option V H...

Страница 26: ...ontal Terminations for All Venting Systems The shaded areas in the diagram below show all allowable combinations of vertical runs with hori zontal terminations Maximum one 90O elbow two 45o elbows equ...

Страница 27: ...flue lengths See chart below for minimumdistancesfromroof Periodicallycheck that the vent is unrestricted Masonry chimneys may take various contours which the flexible liner will accommodate However...

Страница 28: ...pe to length Attachthe 45o elbowtotherigid pipe and ensure that the pipe length when cut with the 45o elbow will seat onto both the starter collar and the 90o elbow Crimped section of rigid pipe seats...

Страница 29: ...on hardening mastic should be run around both the termination and vinyl siding standoff to prevent water from entering and to make a tight seal between the cap and the standoff 7 Stretch the 4 dia fle...

Страница 30: ...1 946 202 Wall Penetration Heat Shield Wall Thimble 2 pcs 1 640 530 P Riser Vent Terminal 1 640 545 P Decorative Wall Trim Black 1 948 128 Tube Mill Pac Screws 1 946 219 p Pipe Adaptor 380 946 Horizon...

Страница 31: ...ter wall of the vent pipe and nearby combustible surfaces is 1 1 4 inch Be sure to check the vent termination clearance requirements from decks windows soffits gas regulators air supply inlets and pub...

Страница 32: ...r mination Neverallowtheventtorundownward This could cause high temperatures and may present the possibility of a fire b The location of the horizontal vent termina tion on an exterior wall must meet...

Страница 33: ...ommended to apply Mill Pac sealant supplied to every inner pipe connection Failure to do so may result in drafting or performance issues not covered under warranty Diagram 5 c Before connecting the ve...

Страница 34: ...is installed under the roofing material and not nailed down until the chimney is installed This allows for small adjustments Note If an offset is necessary in the attic toavoidobstructions itisimporta...

Страница 35: ...Pilot Ignition atalltimes Thiswillavoidnuisance pilot outages during operation of this appli ance See Remote manual for setup of this IPI CPI switch 1 Remove the existing chimney cap 2 Measure the di...

Страница 36: ...e chimney in a convenient location as near as possible to the appliance outlet Cut and frame a hole in the roof for the support The sides of this hole must be vertical with 1 1 4 clearance 2 Place the...

Страница 37: ...specified on the safety label 6 When finished reading manometer turn off the gas valve disconnect the hose and tighten the screw clockwise with a 1 8 flat screwdriver Note Screw should be snug but do...

Страница 38: ...6 Unscrew the pilot orifice with the allen key and replace with the LP pilot orifice in the kit and replace pilot cap 7 Remove burner orifice with a 1 2 wrench and discard Use another wrench to hold...

Страница 39: ...enter Front Log e Embers f Platinum Embers 946 669 supplied with packaged manual Left Front Log Right Front Log 4 Remove Glass front see instructions in manual 3 Remove Cast Front and set the light as...

Страница 40: ...of burner to the other If there is any flame hesitation check that area for any blockage of the burner ports 11 Re install the Glass Front Cast Front and Top 8 Take the embers and place on the burner...

Страница 41: ...Open the right when facing front of appliance access panel by removing 1 screw 2 Install 4 AA batteries into the battery holder Note Remove the batteries when normal opera tion is resumed as the heat...

Страница 42: ...ed with a three pronged grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong recep tacle Do not cut or remove the grounding prong...

Страница 43: ...Hampton H15E 11 Direct Vent Freestanding Gas Stove 43 operating instructions WIRING DIAGRAM WITH THERMOSTAT RESET SWITCH Thermostat Optional Millivolt...

Страница 44: ...the glass while it is hot DO NOT BURN THE APPLIANCE WITHOUT THE GLASS FRONT IN PLACE starting operatingtheappliance pleasereadthe remote control operating instructions packed with remote control to u...

Страница 45: ...cet appareil s il a t plong dans l eau m me partiellement Faites inspecter l appareil par un technicien qualifi et remplacez tout l ment du syst me de contr le ou de commande qui a t plong dans l eau...

Страница 46: ...me pattern has two strong blue flames 1 flowing around the flame sense and 1 flowing across the rear of the burner it does not have to be touching the burner Note If you have an incorrect flame patter...

Страница 47: ...rior portions of the system being exposed to cold weather 4 Inspect joints to verify that no pipe sections or fittings have been disturbed and consequently loosened Alsocheckmechanicalsupportssuch as...

Страница 48: ...ff cast front place front carefully on a soft surface 1 Turn off stove and allow to return to room temperature 2 Shut off electrical supply 3 Lift off cast top and place on a soft surface Lift light a...

Страница 49: ...out of the way Screws 7 Carefully remove the logs and embers 8 Remove burner by removing the 2 screws on each side and then lifting the burner tray out Note Use a magnetic type screwdriver if pos sib...

Страница 50: ...the list should be checked by a licensed gas service technician during the annual service check Your unit may require more frequent maintenance checks if you notice any changes in how it operates Oper...

Страница 51: ...Comes WithLegs 2PerSide Brown 383 227 Cast Left Right Side Comes WithLegs 2PerSide Cream W801015 Touch Up Paint Brown 938 337 Touch Up Paint Cream 9 382 515 Rear Panel Assembly 11 382 516 Valve Cover...

Страница 52: ...Proflm II 7day PV 5 Sec FFRT 0 584 625 911 175 Hand Held Remote Control GTMFL 0 584 042 911 179 ASM 120 Volt Power Cord Assembly 911 173 Valve Remote Wiring Harness 584 924 911 177 4 Position Wire Ha...

Страница 53: ...Hampton H15E 11 Direct Vent Freestanding Gas Stove 53 notes...

Страница 54: ...Control Boards Wiring Switches Blowers Blower Control Module Battery Pack Remote Control Systems 2 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Cryst...

Страница 55: ...ndrafts installation error installation by an unqualified installer incorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels lack of...

Страница 56: ...de the U S should consult their local provincial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the autho...

Страница 57: ...low in order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Produc...

Страница 58: ......

Страница 59: ...Hampton H15E 11 Direct Vent Freestanding Gas Stove 59...

Страница 60: ...me Address _______________________________________________ ___________________________________________________________________ Installer ____________________________________________________________ Ph...

Отзывы: