background image

16

34000 Autry Street, Livonia, MI 48150  |  800.968.5530  |  Fax 734.419.0209  |  www.hamiltonengineering.com  |  LIT91110 REV 06/2018

HWH 129–199.8 W/O 3-WAY

FCD

10/28/09

EVO micro (

HWH

 

129-199.8

 w/o  

3-way

)

Wiring Diagram  with Heating Options

N.T.S.

Description:

Dwg. By:

Date:

Scale:

Customer:

HAMILTON

Dwg. 

No.:

Checked. 

By:

3-way Open to CH

3-way L

3-way Close

Pump P2 L
Pump P2 L

240v

switched

to Pump

K0

K1  

K2

K3

K4

=white

=yellow

=brown

=green

=gray

=orange

=blue

=red

=black

=purple

K5

K6  

K7

K8

K9

K10

K12 

K17

K18

K19

=yellow/green

=yellow/white

=blue/white

=red/white

=black/white

All Wire Size: AWG 18 

+

-

SETPOINT

TEMPERATURE

BURNER ON

RESET

SERVICE

K2

K2

K7

K4

K6

1 2

2

1

X6

X7

20

19

18

17

16

15

13

14

12

11

10

9

5

6

7

8

3

4

2

1

Low Water
Cut-Off

2

1

1

2

K6

K2

K2

K10

K6

On/Off

Switch

4

3

2

 1

K6

K10

K2

Printed  Circuit  Board  FMT914

K6

K2

K10

K1

K0

K10

K6

K2

K2

K2

K2

K2

K5
K5

K3

K3

K6

K10

K2

K7

K8

K6

K10

K6

K2

K10

K6

K2

K6

K2

K6

K6

3.15 Amp

Pressure  Switch

Open  switch

indicates as H-1

Fixed  High Limit

Open  switch 

indicates as H-1

S1

S2

Fan-2

Fan-1

20

19

10

11

12

13

14

15

16

17

18

2

3

4

5

6

7

8

 1

9

18

17

16

15

14

13

12

11

10

 1

9

8

7

6

5

4

3

2

10

9

8

7

4

5

6

2

3

 1

4

5

6

2

3

 1

 1

6
5
4

3

2

Fan

6

5

4

3

2

1

Transformer

Fuse

X 10

X 9

X 8

X5

X 4

X 2

X 1

Gas  valve-1

X 3

Water Flow Switch

Open  switch

indicates as H-1

A

A

K10

K10

K10

Pump L

Pump G

Pump L

Boiler Pump P-1

208 - 240v

Line Voltage

Power L

Power G

Power L

K7

K7

CONTROL

WELL

Tank Sensor

K7

K7

Pump P3 L

Pump P3 L

240v

switched

to Pump

 Pump P-3

Central Heat

Low Temp.

 Pump P-2

DHW Indirect

High Temp.

Indirect coil is 

heated off high 

temp loop - Pump P-2

K2

K6

K7

K6

K2

K6

K2

K6

K2

K6 K2 K7

K6 K2

K6

K2

Содержание EVO 129-599

Страница 1: ...causing property damage personal injury or death WARNING New York Massachusetts SCAQMD CEC Listed MEA 425 05 E Boilers G1 06 06 24A Compliant Rule1146 2 California Energy Commission Heaters G1 06 06 2...

Страница 2: ...Central Heating Only Single Boiler 8 CONFIGURATION 4 Central Heating Only Multiple Boiler Cascade 9 CONFIGURATION 5 Residential Heating w Pumped DHW Single Combi Boiler 10 CONFIGURATION 6 Central Hea...

Страница 3: ...ng Boiler 5 minutes Pump P1 Domestic Hot Water heating zone pump 1 minute Pump P2 Diverting Valve Zone Transport Pump 5 minutes Pump P3 DISPLAY The 3 digit display will show different information duri...

Страница 4: ...EV 06 2018 GENERAL DESCRIPTION That are represented by The following pages contain drawings that apply to all models of EVO products In addition most drawings reference a Low Loss Header which may als...

Страница 5: ...wing can be done 1 Adjust the heater minimum and maximum temperature setting via the red wheel located on the display panel within the range of 50 159 F Parameter 2 EA 2 EB 2 An external on off tank t...

Страница 6: ...range of 50 159 F Parameter 2 EA 2 EB It is important to set the red potentiometer wheel to the desired setpoint on the Lag heaters with the power off to the Lead heater This way in the event of a con...

Страница 7: ...ermistor is connected to terminals 1 2 or 9 10 26 27 depending on model The control will automatically sense the presence of the sensor When an outside temperature sensor is connected the flow tempera...

Страница 8: ...195 F Parameter 2 EB 2 EA 2 Outdoor temperature reset can be enabled by connecting a 10k ohm sensor to terminals 1 2 or 9 10 26 27 depending on model this will be automatically sensed by the FMT 914...

Страница 9: ...be controlled based on the Room Thermostat must add heating harness WRE74090 and wire to P3 leads Caution maximum available wattage for external load on the FMT 914 control board is 550 watts If pumps...

Страница 10: ...ry heating loop In this configuration the following can be done 1 Adjust the boiler minimum and maximum temperature setting via the potentiometer located on the display panel within the range of 50 19...

Страница 11: ...nfiguration the following can be done 1 Adjust the boiler minimum and maximum temperature setting via the potentiometer located on the display panel within the range of 50 192 F Parameter 2 EB 2 EA 2...

Страница 12: ...entiometer located on the display panel within the range of 50 192 F Parameter 2 EB 2 EA 2 Set boiler water temperature to the DHW tank Factory default is 185 Parameter 2 CE 3 Set the DHW water temper...

Страница 13: ...ting valve is to be connected to the harness leads labeled 3 way Open 3 way Close and 3 way L In this configuration the following can be done 1 Adjust the boiler minimum and maximum temperature settin...

Страница 14: ...maximum temperature setting via the potentiometer located on the display panel within the range of 95 195 F Parameter 2 EB 2 EA 2 Set the flow temperature to the DHW tank Factory default is 185 F Par...

Страница 15: ...15 34000 Autry Street Livonia MI 48150 800 968 5530 Fax 734 419 0209 www hamiltonengineering com LIT91110 REV 06 2018 HWD 129 199 8 STANDARD WIRING...

Страница 16: ...1 1 2 K6 K2 K2 K10 K6 On Off Switch 4 3 2 1 K6 K10 K2 Printed Circuit Board FMT914 K6 K2 K10 K1 K0 K10 K6 K2 K2 K2 K2 K2 K5 K5 K3 K3 K6 K10 K2 K7 K8 K6 K10 K6 K2 K10 K6 K2 K6 K2 K6 K6 3 15 Amp Pressu...

Страница 17: ...17 34000 Autry Street Livonia MI 48150 800 968 5530 Fax 734 419 0209 www hamiltonengineering com LIT91110 REV 06 2018 HWH 129 199 8 W 3 WAY...

Страница 18: ...ow white blue white red white black white K10 K12 K17 K18 K19 K5 K6 K7 K8 K9 orange blue red black purple white yellow brown green gray K0 K1 K2 K3 K4 K6 K6 K2 K6 K2 K6 K10 K2 K6 K10 K6 K8 K7 K2 K10 K...

Страница 19: ...X 4 X 2 X 1 Gas valve 1 Power Supply Cascade Connection 15 3 16 17 20 19 18 4 2 1 4 3 2 1 X 3 K2 K6 K10 K10 K6 K2 6 5 Thermostat Central Heat Room K1 K1 K4 K4 0 10 VDC 7 8 10 9 Sensor Outside K8 K8 1...

Страница 20: ...Fuse X 10 X 9 X 8 X5 X 4 X 2 X 1 Gas valve 1 Power Supply Cascade Connection 15 3 16 17 20 19 18 4 2 1 4 3 2 1 X 3 K2 K6 K10 K10 K6 K2 6 5 Thermostat Central Heat Room K1 K1 K4 K4 0 10 VDC 7 8 10 9 S...

Страница 21: ...ndirect OPEN THERM PCB BURNER L1 24 ST 3 8 7 Thermostat Remote Additional Heat Source Dry Contact Dry Contact Signal Lock Out External L2 K2 Pressure switch Open switch indicates as H 1 High limit the...

Отзывы: