34000 Autry Street, Livonia, MI 48150  |  800.968.5530  |  Fax 734.419.0209  |  www.hamiltonengineering.com  |  LIT91110 REV 06/2018

HWH 199-599 W/3-WAY

Pump P1 L  

Low Water
Cut Off

Pump P1 L

K9

K9

On/Off

K2

208 - 240 VAC

-

+

L   

L

L

+

-

SETPOINT

TEMPERATURE

BURNER ON

RESET

SERVICE

60 Hz, 
208-240 VAC

L   

Sensor

External 

Pump

Printed Circuit Board FMT914

Outlet sensor

Inlet sensor

Model  599 only

K6

K2

K10

K0

K10

K6

K2

K10

K6

K2

K5

K5

K3

K3

K6

K10

K2

K7

K8

K6

K10

K6

K2

K10

K6

K2

K0

K0

K6

K6

K0
K1  
K2
K3
K4

=white
=yellow
=brown
=green
=gray

=orange
=blue
=red
=black
=purple

K5
K6  
K7
K8
K9

K10
K12 
K17
K18
K19

=yellow/green
=yellow/white
=blue/white
=red/white
=black/white

3.15  Amp

S1

S2

Switch

fan-2

fan-1

20

19

10

11

12

13

14

15

16

17

18

2

3

4

5

6

7

8

 1

9

Gas valve-2

18
17
16
15
14
13
12
11
10

 1

9
8
7
6
5
4
3
2

10

9
8
7

4

5

6

2

3

 1

4

5

6

2

3

 1

 1

6

5

4

3

2

fan

6

5

4

3

2

1

Transformer

Fuse

X  10

X 9

X 8

X5

X 4

X 2

X 1

Gas valve-1

Power Supply 

Cascade
Connection

15

3

16

17

20

19

18

4

2

1

4

3

2

 1

X 3

K2

K6

K10

K10

K6

K2

6

5

Thermostat
Central Heat

Room

K1

K1

-

+

K4

K4

0-10 VDC

7

8

10

9

Sensor

Outside

K8

K8

15-16-17

18-19-20

Pump P3 L

Pump P3 L

3-way Open to CH

3-way L

3-way Close

K7

K7

Additional
Heat Source
Dry Contact

Dry Contact

Signal

Lock Out

 1 2

2

 1

X7

X6

K4

K6

13

14

12

11

K6

K7

ST-5

15

16

17

18

19

20

Pump P1 G 

1

2

K1

240v

switched

to  Pump

CONTROL

WELL

K2

K2

K2

K2

K2

K2

Pressure Switch
Open switch
indicates as H-1

Fixed High Limit
Open switch 
indicates as H-1

Water Flow Switch
Open switch
indicates as H-1

ST-1

ST-2

ST-3

ST-4

ST-7

ST-6

VST-6

VST-7

A

A

P-1

Boiler Pump

Tank Sensor

Line Voltage

FCD

10/28/09

N.T.S.

EVO duo (HWH 199-599 w/3-way)
Wiring Diagram with  Heating  Options

All Wire Size: AWG 18 

Power L

Power G 

Power L

34000 Autry
Livonia, MI 48150

PH: (800) 968-5530
Fax: (734) 419-0209

Description:

Dwg. By:

Date:

Scale:

Customer:

HAMILTON

ENGINEERING

Dwg. 
No.:

Checked. 
By:

P-3

Heating Pump

Low Temp

Close

N

N

Open

24V  Transformer

Содержание EVO 129-599

Страница 1: ...causing property damage personal injury or death WARNING New York Massachusetts SCAQMD CEC Listed MEA 425 05 E Boilers G1 06 06 24A Compliant Rule1146 2 California Energy Commission Heaters G1 06 06 2...

Страница 2: ...Central Heating Only Single Boiler 8 CONFIGURATION 4 Central Heating Only Multiple Boiler Cascade 9 CONFIGURATION 5 Residential Heating w Pumped DHW Single Combi Boiler 10 CONFIGURATION 6 Central Hea...

Страница 3: ...ng Boiler 5 minutes Pump P1 Domestic Hot Water heating zone pump 1 minute Pump P2 Diverting Valve Zone Transport Pump 5 minutes Pump P3 DISPLAY The 3 digit display will show different information duri...

Страница 4: ...EV 06 2018 GENERAL DESCRIPTION That are represented by The following pages contain drawings that apply to all models of EVO products In addition most drawings reference a Low Loss Header which may als...

Страница 5: ...wing can be done 1 Adjust the heater minimum and maximum temperature setting via the red wheel located on the display panel within the range of 50 159 F Parameter 2 EA 2 EB 2 An external on off tank t...

Страница 6: ...range of 50 159 F Parameter 2 EA 2 EB It is important to set the red potentiometer wheel to the desired setpoint on the Lag heaters with the power off to the Lead heater This way in the event of a con...

Страница 7: ...ermistor is connected to terminals 1 2 or 9 10 26 27 depending on model The control will automatically sense the presence of the sensor When an outside temperature sensor is connected the flow tempera...

Страница 8: ...195 F Parameter 2 EB 2 EA 2 Outdoor temperature reset can be enabled by connecting a 10k ohm sensor to terminals 1 2 or 9 10 26 27 depending on model this will be automatically sensed by the FMT 914...

Страница 9: ...be controlled based on the Room Thermostat must add heating harness WRE74090 and wire to P3 leads Caution maximum available wattage for external load on the FMT 914 control board is 550 watts If pumps...

Страница 10: ...ry heating loop In this configuration the following can be done 1 Adjust the boiler minimum and maximum temperature setting via the potentiometer located on the display panel within the range of 50 19...

Страница 11: ...nfiguration the following can be done 1 Adjust the boiler minimum and maximum temperature setting via the potentiometer located on the display panel within the range of 50 192 F Parameter 2 EB 2 EA 2...

Страница 12: ...entiometer located on the display panel within the range of 50 192 F Parameter 2 EB 2 EA 2 Set boiler water temperature to the DHW tank Factory default is 185 Parameter 2 CE 3 Set the DHW water temper...

Страница 13: ...ting valve is to be connected to the harness leads labeled 3 way Open 3 way Close and 3 way L In this configuration the following can be done 1 Adjust the boiler minimum and maximum temperature settin...

Страница 14: ...maximum temperature setting via the potentiometer located on the display panel within the range of 95 195 F Parameter 2 EB 2 EA 2 Set the flow temperature to the DHW tank Factory default is 185 F Par...

Страница 15: ...15 34000 Autry Street Livonia MI 48150 800 968 5530 Fax 734 419 0209 www hamiltonengineering com LIT91110 REV 06 2018 HWD 129 199 8 STANDARD WIRING...

Страница 16: ...1 1 2 K6 K2 K2 K10 K6 On Off Switch 4 3 2 1 K6 K10 K2 Printed Circuit Board FMT914 K6 K2 K10 K1 K0 K10 K6 K2 K2 K2 K2 K2 K5 K5 K3 K3 K6 K10 K2 K7 K8 K6 K10 K6 K2 K10 K6 K2 K6 K2 K6 K6 3 15 Amp Pressu...

Страница 17: ...17 34000 Autry Street Livonia MI 48150 800 968 5530 Fax 734 419 0209 www hamiltonengineering com LIT91110 REV 06 2018 HWH 129 199 8 W 3 WAY...

Страница 18: ...ow white blue white red white black white K10 K12 K17 K18 K19 K5 K6 K7 K8 K9 orange blue red black purple white yellow brown green gray K0 K1 K2 K3 K4 K6 K6 K2 K6 K2 K6 K10 K2 K6 K10 K6 K8 K7 K2 K10 K...

Страница 19: ...X 4 X 2 X 1 Gas valve 1 Power Supply Cascade Connection 15 3 16 17 20 19 18 4 2 1 4 3 2 1 X 3 K2 K6 K10 K10 K6 K2 6 5 Thermostat Central Heat Room K1 K1 K4 K4 0 10 VDC 7 8 10 9 Sensor Outside K8 K8 1...

Страница 20: ...Fuse X 10 X 9 X 8 X5 X 4 X 2 X 1 Gas valve 1 Power Supply Cascade Connection 15 3 16 17 20 19 18 4 2 1 4 3 2 1 X 3 K2 K6 K10 K10 K6 K2 6 5 Thermostat Central Heat Room K1 K1 K4 K4 0 10 VDC 7 8 10 9 S...

Страница 21: ...ndirect OPEN THERM PCB BURNER L1 24 ST 3 8 7 Thermostat Remote Additional Heat Source Dry Contact Dry Contact Signal Lock Out External L2 K2 Pressure switch Open switch indicates as H 1 High limit the...

Отзывы: