HWH 79-599 UNIVERSAL

03/23/09

34000 Autry St.

Livonia, MI   48150

PH: (800) 968-5530

Fax: (734) 419-0209

Description:

Dwg. By:

Date:

Scale:

Customer:

HAMILTON

ENGINEERING

Dwg. 

No.:

Checked. 

By:

NTS

K0

K1  

K2

K3

K4

=white

=yellow

=brown

=green

=grey

=orange

=blue

=red

=black

=purple

K5

K6  

K7

K8

K9

K10 =yellow/green

+

-

SETPOINT

TEMPERATURE

BURNER ON

RESET

SERVICE

X 3

2

1

3

4

5

6

28

26

23

25

22

L1

L1

Sensor

Indirect

Sensor

Outdoor

Divertor Valve Indirect

L1

Power Supply

Gas Valve-1

X 1

X 2

X 4

X5

X 8

X 9

X 10

Fuse 3.15A

Transformer

1

2

3

4

5

6

fan

2

3

4

5

6

 1

 1

3

2

6

5

4

 1

3
2

6
5
4

7

8

9

10

2

3

4

5

6

7

8

9

 1 10

11

12

13

14

15

16

17

18

Gas Valve-2

9

 1

8

7

6

5
4
3
2

18
17
16
15

14
13
12
11

10

19

20

fan-1

fan-2

AMP universal 

MALE N LOK 350766-1

S1

S2

Main

ST-4

ST-2

ST-6

ST-7

K6

K3

K5

K6
K2

K6

K2

Sensor

or

Aquastat

Pump 2-indirect

OPEN THERM PCB

BURNER

L1

24

ST-3

8

7

Thermostat

Remote

Additional

Heat 

Source
Dry 

Contact

Dry 

Contact

Signal

Lock Out

External

L2

K2

Pressure 

switch

Open switch

indicates as H-1

High limit

thermostat

Open switch 

indicatesas H-1

12

11

10

9

+     -

Cascade

Connection

ST-1

19

17

16

15

13 14

Pump 3 

L2

Bridge

+    -

0-10

VDC

20 21

1

2

1 2

M

ol

ex

2121

L2 

Pump 1 

208-240 Vac

18

27

X7

 1 2

5

4

3

X6

operatin

g

fault

Pump-2/close

Pump-1

open

Pump-2/comm.

K6

Pump-3

Pump-3

Pump-1

L1

L2

K2

K2

K6

K1

0

K2

K6

K1

0

switch

Gasvalve
Gasvalve

K2

K6

K2

K2

supply L2

supply L1

K2

K6

K1

0

K1

0

K1

0

K1

0

K10

K10

K10

1A

2A

2

 1

open

close

com.

L1

L2 

K0

K9

2

1

Cascade PCB

1

2

Thermostat X1/9-18

or OpenTherm PCB X3

M

ol

ex

2020

M

ol

ex

2020

ST-5

K1

0

K2

K6

K2

K1

K1

flow sensor

K5

K3

return sensor

K2

K2

K2

K2

K2

K9

K9

power supply

fan

pwm/hall

signal

K4

K8

K7

K7

K4

K8

K7

K7

K1

K9

K9

K8

not

 in

 use

K8

K8

K7

K7

K7

K8

K0

K7

1

2

Molex2020

1

2

Molex2020

+

-

K2

K1

0

K1

K3

K1

Universal Wiring Diagram

HW 79 - 599

LowWater Cut Off

K2

Water Flow switch

Open switch

indicates as H-1

Additional Safety Devices

Rear wall

high limit

thermostat

Burner door

high limit

thermostat

Содержание EVO 129-599

Страница 1: ...causing property damage personal injury or death WARNING New York Massachusetts SCAQMD CEC Listed MEA 425 05 E Boilers G1 06 06 24A Compliant Rule1146 2 California Energy Commission Heaters G1 06 06 2...

Страница 2: ...Central Heating Only Single Boiler 8 CONFIGURATION 4 Central Heating Only Multiple Boiler Cascade 9 CONFIGURATION 5 Residential Heating w Pumped DHW Single Combi Boiler 10 CONFIGURATION 6 Central Hea...

Страница 3: ...ng Boiler 5 minutes Pump P1 Domestic Hot Water heating zone pump 1 minute Pump P2 Diverting Valve Zone Transport Pump 5 minutes Pump P3 DISPLAY The 3 digit display will show different information duri...

Страница 4: ...EV 06 2018 GENERAL DESCRIPTION That are represented by The following pages contain drawings that apply to all models of EVO products In addition most drawings reference a Low Loss Header which may als...

Страница 5: ...wing can be done 1 Adjust the heater minimum and maximum temperature setting via the red wheel located on the display panel within the range of 50 159 F Parameter 2 EA 2 EB 2 An external on off tank t...

Страница 6: ...range of 50 159 F Parameter 2 EA 2 EB It is important to set the red potentiometer wheel to the desired setpoint on the Lag heaters with the power off to the Lead heater This way in the event of a con...

Страница 7: ...ermistor is connected to terminals 1 2 or 9 10 26 27 depending on model The control will automatically sense the presence of the sensor When an outside temperature sensor is connected the flow tempera...

Страница 8: ...195 F Parameter 2 EB 2 EA 2 Outdoor temperature reset can be enabled by connecting a 10k ohm sensor to terminals 1 2 or 9 10 26 27 depending on model this will be automatically sensed by the FMT 914...

Страница 9: ...be controlled based on the Room Thermostat must add heating harness WRE74090 and wire to P3 leads Caution maximum available wattage for external load on the FMT 914 control board is 550 watts If pumps...

Страница 10: ...ry heating loop In this configuration the following can be done 1 Adjust the boiler minimum and maximum temperature setting via the potentiometer located on the display panel within the range of 50 19...

Страница 11: ...nfiguration the following can be done 1 Adjust the boiler minimum and maximum temperature setting via the potentiometer located on the display panel within the range of 50 192 F Parameter 2 EB 2 EA 2...

Страница 12: ...entiometer located on the display panel within the range of 50 192 F Parameter 2 EB 2 EA 2 Set boiler water temperature to the DHW tank Factory default is 185 Parameter 2 CE 3 Set the DHW water temper...

Страница 13: ...ting valve is to be connected to the harness leads labeled 3 way Open 3 way Close and 3 way L In this configuration the following can be done 1 Adjust the boiler minimum and maximum temperature settin...

Страница 14: ...maximum temperature setting via the potentiometer located on the display panel within the range of 95 195 F Parameter 2 EB 2 EA 2 Set the flow temperature to the DHW tank Factory default is 185 F Par...

Страница 15: ...15 34000 Autry Street Livonia MI 48150 800 968 5530 Fax 734 419 0209 www hamiltonengineering com LIT91110 REV 06 2018 HWD 129 199 8 STANDARD WIRING...

Страница 16: ...1 1 2 K6 K2 K2 K10 K6 On Off Switch 4 3 2 1 K6 K10 K2 Printed Circuit Board FMT914 K6 K2 K10 K1 K0 K10 K6 K2 K2 K2 K2 K2 K5 K5 K3 K3 K6 K10 K2 K7 K8 K6 K10 K6 K2 K10 K6 K2 K6 K2 K6 K6 3 15 Amp Pressu...

Страница 17: ...17 34000 Autry Street Livonia MI 48150 800 968 5530 Fax 734 419 0209 www hamiltonengineering com LIT91110 REV 06 2018 HWH 129 199 8 W 3 WAY...

Страница 18: ...ow white blue white red white black white K10 K12 K17 K18 K19 K5 K6 K7 K8 K9 orange blue red black purple white yellow brown green gray K0 K1 K2 K3 K4 K6 K6 K2 K6 K2 K6 K10 K2 K6 K10 K6 K8 K7 K2 K10 K...

Страница 19: ...X 4 X 2 X 1 Gas valve 1 Power Supply Cascade Connection 15 3 16 17 20 19 18 4 2 1 4 3 2 1 X 3 K2 K6 K10 K10 K6 K2 6 5 Thermostat Central Heat Room K1 K1 K4 K4 0 10 VDC 7 8 10 9 Sensor Outside K8 K8 1...

Страница 20: ...Fuse X 10 X 9 X 8 X5 X 4 X 2 X 1 Gas valve 1 Power Supply Cascade Connection 15 3 16 17 20 19 18 4 2 1 4 3 2 1 X 3 K2 K6 K10 K10 K6 K2 6 5 Thermostat Central Heat Room K1 K1 K4 K4 0 10 VDC 7 8 10 9 S...

Страница 21: ...ndirect OPEN THERM PCB BURNER L1 24 ST 3 8 7 Thermostat Remote Additional Heat Source Dry Contact Dry Contact Signal Lock Out External L2 K2 Pressure switch Open switch indicates as H 1 High limit the...

Отзывы: