45
Step 8 - Record the Rest of the Line Segments
Record the rest of the line segments, following the
recommended sequence from Plane6.
Notes on taking data
:
1.
Display Value Tolerance
- Pay attention to the
H axis value. If the value gets higher than
30,000 µin. (760 µm), then the Plane6 data
display will turn orange indicating that this is
too far off center in the horizontal axis. This
may mean the laser fixture moved. Check to
make sure the laser fixture is still against the
straight edge. If not, then move them together
again.
Move the target to the end of the straight edge
and see if the orange color disappears. If so
this means it’s back in spec. Then hit
Clear
Line
XX
to restart the data taking for the line
segment.
If it’s still orange, you can simply adjust the H
axis until it’s less than 25,000. Then hit
Clear
Line
XX
and retake the data for that line.
2.
Checking Recorded Data Points
- You can
always check data values for a given point by
hovering over it and seeing the values or by
clicking on it and seeing the values in the table.
3.
Retaking a Data Point -
You can also click on
a point and retake the data point if you think it
is wrong.