Slide 89
9.
Drive
The brake must be capable of stopping the machine on a level road within 0.19 m per
km/h.
At a maximum speed of 8 km/h, this means that the maximum braking distance must
not exceed 1.52 m. Check this after carrying out work at the brake system and as part
of regular maintenance.
This value must be achieved when actuating the brake tip switch S10.
The service brake function of the SCM B260R is exclusively realised via the drive
control.
The magnetic brake on the motor is merely the parking brake.
9.1.4
Brake – checking the brake function
Содержание Scrubmaster B260 R
Страница 64: ...Slide 64 Figure 7 2a Figure 7 2b 7 Mechanical components 7 1 Squeegee...
Страница 66: ...Slide 66 Figure 7 4 7 Mechanical components Height adjustment 7 1 Squeegee...
Страница 69: ...Slide 69 7 Mechanical components 7 2 1 Rotating brush heads contact pressure stages Figure 7 5 A B C...
Страница 100: ...180 130 170 150 120 Figure 9 5 Slide 100 9 Drive 9 2 4 Steering angle sensor...
Страница 108: ...Slide 108 10 2 Service alarm clock 3 3 1 1 The service alarm clock is set via the Hako diagnostic system...
Страница 119: ...Slide 119 13 Electrical components 13 2 Dash board A02 Position of connectors on Dash board A02...