Clamping force tester TESTit – Measuring
7 Measuring
7.1 Precondition
NOTE!
Check the capacity of the measuring heads
battery.
If necessary connect the measuring head
with the included USB cable to the tablet or
connect the measuring head with the plug to
the power line.
Keep the connection until the battery is
charged completely.
NOTE!
The measuring head may only be used for
smooth round clamping points.
Check the surface of the clamping point.
NOTE!
While clamping the measuring head may not
touch to a work piece end-stop or to the man-
drels body and/or housing.
Check the clamping diameter of the seg-
mented clamping bushing and/or the clamp-
ing head!
NOTE!
O. D. clamping:
Put in the measuring head in a way, that it
touches the clamping head.
I. D. clamping MANDO T212 / MANDO T812:
To account the stroke distance, place the
measuring head in such a way that the dis-
tance to the segmented clamping bushing is
approximately 5 mm.
24
Order H49 7144.907-333