1
Installation and Maintenance Manual, Compact CA
Table 3.8
Mounting the motor without a
mounting tool
The motor can be mounted onto the driven shaft
without using a mounting tool, though this is
more difficult and takes longer time. However, it
is easier to mount the motor if during mounting
the compressed air trapped within the hollow
shaft is evacuated. To do this, remove the End
cover as described in "Mounting the motor with
a mounting tool"
Align the motor with the driven shaft using
an overhead crane or lifting truck and press
it carefully onto the shaft
so that the length
stated in the table beside is obtained, see
Fig. 3.11.
To achieve the highest possible oil level in the
motor housing, the motor must be turned until
the drain outlets are positioned according to
fig 3.1.
Fig. 3.12
Fig. 3.11 Without stress relieving groove
Fig. 3.11a With stress relieving groove
Installation
Vertical line
D
D1
Motor
Lenght
B mm
B in
CA 50
CA 70
CA 100
CA 140
CA 10
71,5
71,5
84,5
84,5
105
,81
,81
3,33
3,33
4,13