Habasit Italiana S.p.A.
Vittorio Veneto 31029 (TV)
Tel.: ++39(0)438.9113
Fax. ++39(0)438.200545
Regulating Unit PMR-07
Author:
A.T. / KM
CONTROL UNIT
Edition: 04/2006
Page
E-10
Replaces: 10/2005
T
ABLE
9
-
T
ABLE WITH WORKING PARAMETERS OF
PMR-07
WORKING PARAMETERS OF PMR-07
( * ) The Passwords "5" and "101" are not modifiable
Ord.
Vis.
Pass-
word
PARAMETER PLANNING
CONFIGURATION
from to Unit from
to
Default code
Unit
Key led
Upper Plate Set-Point
UP1
dn1
1 / °C
Key led
Lower Plate Set-Point
UP2
dn2
1 / °C
Key led
Welding time set
0
999
1 / sec
(Unt=1)
1 / min
(Unt=60)
1
101
Cooling phase stop set-point
20
70
50
SPr
1 / °C
2
101
Welding time scale
1
60
60
Unt
1 / 60
3
101
Upper NTC sensor off-set
-20
20
0
OF1
0,5 / °C
4
101
Lower NTC sensor off-set
-20
20
0
OF2
0,5 / °C
5
101
Valve of air blowing ON:1 OFF:0
1
0
1
Ar
1 / unit
6
101
Air blowing time
0
500
60
SAr
1 / second
7
101
RS485 Address of central unit
1
32
1
Add
1 / unit
8
101
Upper plate: max set-point value
100
200
200
UP1
1 / °C
9
101
Upper plate: min set-point value
20
50
20
dn1
1 / °C
10
101
Lower plate: max set-point value
100
200
200
UP2
1 / °C
11
101
Lower plate: min set-point value
20
50
20
dn2
1 / °C
12
101
Window of sensibility of calculation
( +/- from Set-Point value)
0
20
0
InS
0,5 / °C
13
101
Window of tolerance
( +/- from Set-Point value)
3
10
3
tOL
1 / °C
14
101
PID valve ( + )
0
70
10
dP1
1 / unit %
UP1/UP2
15
101
PID valve ( - )
0
70
10
dP2
1 / unit %
UP1/UP2
16
101
Proportional constant
0
20
7
cP
1 / unit
17
101
Derivative constant
0
99
35
cd
1 / unit
18
101
Integral constant
0
20
2
cI
1 / unit
19
101
Min time power relay on
1
30
1
tOn
0,5 / second
20
101
Min time power relay off
1
30
1
tOF
0,5 / second
21
101
Min recalculative time PID function
1
20
4
tPd
1 / second
22
101
NTC sensor calibration for TC
coupler
T° NTC
- 10°C
T° NTC
+ 10°C
-
ntc
0,5 / °C
23
5
Upper plate: lower point calibration
dn1
100
-
t11
1 / °C
24
5
Upper plate: upper point calibration
120
UP1
-
t12
1 / °C
25
5
Lower plate: lower point calibration
dn2
100
-
t21
1 / °C
26
5
Lower plate: upper point calibration
120
UP2
-
t22
1 / °C
Regulating Unit PMR-07