Habasit Italiana S.p.A.
Vittorio Veneto 31029 (TV)
Tel.: ++39(0)438.9113
Fax. ++39(0)438.200545
Regulating Unit PMR-07
Author:
A.T. / KM
CONTROL UNIT
Edition: 04/2006
Page
E-3
Replaces: 10/2005
E.1.1
E
LEMENTS AND THEIR FUNCTIONS
T
ABLE
8
-
T
ABLE OF ELEMENTS AND THEIR FUNCTIONS
Label Name
Function
1
[START]
Starts the joining cycle
Its green indicator is on while the joining cycle runs
Its red indicator blinks while the cycle is interrupted and the
controller is waiting for the operator’s decision
2
[STOP]
Breaks the joining cycle
Its red indicator blinks while the cycle is interrupted and the
controller is waiting for the operator’s decision
The indicator is steadily lit in standby mode (cycle completed or
control waiting for input of data)
3
[PROG]
In Standby mode, switches to programming mode (during which
parameters can be input).
During the joining cycle, temporarily switches to display of the set
value.
Its yellow indicator is lit when in programming mode.
4
5
6
[TOP TEMPERATURE]
[BOTTOM TEMPERATURE]
[PRESSING TIME]
These three mode switches select input or display mode for the
respective parameter. The yellow indicator of the active
parameter is lit.
7, 8
[UP, DOWN]
In programming or parameterization mode: increase or decrease
current parameter.
With interrupted joining cycle: select cycle phase to continue with.
9
[DISPLAY]
Multifunction three-digit display.
10
11
<TOP HEATER ON>
indicator
<BOTTOM HEATER ON>
indicator
Lit while respective heater receives power (constantly lit during
heating up, starts to cycle after reaching temperature, (heater is
holding temperature))
12 <PRESSING
TIME
ON>
indicator
Lit as soon as joining time count down has started (as soon as
both plates have reached their setting temperatures)
13 <COOLING
PHASE>
indicator
Lit during the cooling cycle (after joining time has counted down)
Regulating Unit PMR-07