26
January 2004
PARAM
ETER
DISPLAY
The
PARAMETER DISPLAY
can be selected at any time by pressing the PARAM DGNOS button.
Changes to parameters can be made when in any mode except when running a program. The CUR-
SOR
up
and
down
buttons move to different parameters and the PAGE UP and PAGE DOWN
buttons move through groups of parameters. Parameters 1, 15, 29, 43, and 57 are displayed as a single page
of discrete items. Selecting among the items is done with the CURSOR
left
and
right
buttons or by using the
handle. Parameters cannot be changed with the servos on. The EMERGENCY STOP button is to turn the
servos off.
For machines with the fifth axis option, the parameter display organization has been modified to accommodate
the extra axis parameters. Parameter numbers have remained the same as in a four-axis control. Additional
parameters have been added for the fifth axis.
The parameters have been reorganized so that logically-associated parameters are grouped together. These
logical groupings are placed together into contiguous screens called pages. The most commonly changed
parameters have been placed at the beginning of the page list.
Pressing the HOME key displays the first parameter page. Pressing the PAGE DOWN key will display the
next page of parameters. The END key displays the last parameter page. Pressing the PAGE UP key will
display the preceding pages of parameters. All other features on the parameters display have remained the
same. So, if you are unfamiliar with the new format of the parameters, you can still search by parameter
number. Enter the number of the parameter you want to see and press the
up
or
down
arrow key. The page
that the parameter is on will be displayed and the parameter being searched for will be highlighted.
Caution
: DO NOT CHANGE PARAMETERS unless you know exactly what needs to be changed and why, and
that you have made all the correct inquiries within your company and to Haas service personnel. If a parameter
is changed without proper assistance, you may void the warranty of machine.
D
IA
GNOS
TICS
DISPLAY
The
DIAGNOSTICS DATA DISPLAY
can be selected at any time by pressing the PARAM DGNOS
button a second time. There are two pages of diagnostic data and the PAGE UP and PAGE DOWN
buttons are used to select between them. After this, the current run time and the number of tool
changes are displayed.
A five-axis control has additional diagnostic data to be aware of: The first page of diagnostic data shows two
discrete outputs that control the rotary axes brakes; they are labeled Brake 4th Axis and Brake 5th Axis.
The 4th axis is synonymous with the A axis, and the 5th axis is synonymous with the B axis. If the Air Brake
Parameter for the axis is set to 1, the HAAS control un-clamps the brake whenever motion is commanded to
the rotary axis and sets the brake back to its previous state as soon as the motion stops. The brake is
activated by a relay. The two discrete outputs show the state of the brake relays. If the output is high (1) the
brake is un-clamped. When machine is first powered up the brake will be clamped, so the output will be low
(0). When the brake is un-clamped the message A UNCLMP (4th Axis) or B UNCLMP (5th Axis) is displayed
in the message area near the bottom of the display.
The M11 and M13 codes command the brake to be un-clamped. When these codes are in effect, the axis
brake will remain un-clamped even after motion has stopped.
The second page of diagnostic data shows the status of inputs from the motor interface board.