15
January 2004
Example:
The following code sequence demonstrates how the spigot could be commanded. Tool 2 using
coolant position 6 on offset H02 and position 5 on offset H22.
Setting 15 would need to be OFF to do this.
Tool Offset Display
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
COOLANT
---------
LENGTH
---------- -------
DIAMETER
-------
TOOL
POSITION
GEOMETERY WEAR GEOMETRY WEAR
FLUTES
1
3
-12.3568
-0.0045
0.7500
-0.0025
6
2
6
-9.3612
-0.0125
0.5000
-0.0015
4
...
...
......
.......
.......
.......
...
...
...
......
.......
.......
.......
...
...
...
......
.......
.......
.......
...
22
5
-9.3612
-0.0125
0.5000
-0.0015
4
Part Program
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
O00001
(Coolant positioning example)
T1 M06
(Tool 1)
G90 G54 G00 X0.5 Y-0.5 S1400 M03
G43 H01 Z1. M08
(Moves spigot to the H01 coolant offset register location)
.
.
.
T2 M06
(Tool 2)
G90 G54 G00 X0.5 Y-0.5 S900 M03
G43 H02 Z1. M08
(Moves spigot to the H02 coolant offset register location)
.
.
.
G43 H22 Z0.1
(Position to new location with a second offset H22)
(More than one offset number can be used for a tool if needed)
.
M30
Or you could just program in an M35 in place of the H22 line to position spigot up one position.