Operation Manual – Cluster
H3C S5600 Series Ethernet Switches
Chapter 1 Cluster
1-25
# Enable the cluster function.
[Sysname] cluster enable
2)
Configure the management device
# Add port GigabitEthernet 1/0/1 to VLAN 2.
<Sysname> system-view
[Sysname] vlan 2
[Sysname-vlan2] port GigabitEthernet 1/0/1
[Sysname-vlan2] quit
# Configure the IP address of VLAN-interface 2 as 163.172.55.1.
[Sysname] interface Vlan-interface 2
[Sysname-Vlan-interface2] ip address 163.172.55.1 255.255.255.0
[Sysname-Vlan-interface2] quit
# Disable NDP on the uplink port GigabitEthernet 1/0/1.
[Sysname] ndp enable
[Sysname] undo ndp enable interface GigabitEthernet 1/0/1
[Sysname] interface GigabitEthernet 1/0/1
[Sysname-GigabitEthernet1/0/1] undo ntdp enable
[Sysname-GigabitEthernet1/0/1] quit
# Enable NDP on GigabitEthernet 1/0/2 and GigabitEthernet 1/0/3.
[Sysname] interface GigabitEthernet 1/0/2
[Sysname-GigabitEthernet1/0/2] ndp enable
[Sysname-GigabitEthernet1/0/2] quit
[Sysname] interface GigabitEthernet 1/0/3
[Sysname-GigabitEthernet1/0/3] ndp enable
[Sysname-GigabitEthernet1/0/3] quit
# Set the hold time of NDP information to 200 seconds.
[Sysname] ndp timer aging 200
# Set the interval between sending NDP packets to 70 seconds.
[Sysname] ndp timer hello 70
# Enable NTDP globally and on GigabitEthernet 1/0/2 and GigabitEthernet 1/0/3.
[Sysname] ntdp enable
[Sysname] interface GigabitEthernet 1/0/2
[Sysname-GigabitEthernet1/0/2] ntdp enable
[Sysname-GigabitEthernet1/0/2] quit
[Sysname] interface GigabitEthernet 1/0/3
[Sysname-GigabitEthernet1/0/3] ntdp enable
[Sysname-GigabitEthernet1/0/3] quit
# Set the topology collection range to 2 hops.