Operation Manual – HWPing
H3C S5600 Series Ethernet Switches
Chapter 1 HWPing Configuration
1-20
To do…
Use the command…
Remarks
Configure the number of
consecutive unsuccessful
HWPing probes before
Trap output
probe-failtimes times
Optional
By default, Trap
messages are sent each
time a probe fails.
1.2.3 Displaying HWPing Configuration
To do…
Use the command…
Remarks
Display test history
display hwping history
[
administrator-name operation-tag
]
Display the results of the
latest test
display hwping results
[
administrator-name operation-tag
]
Available in
any view.
1.3 HWPing Configuration Examples
1.3.1 ICMP Test
I. Network requirements
An H3C S5600 series Ethernet switch serves as the HWPing client. A HWPing ICMP
test between the switch and another switch uses ICMP to test the round trip time (RTT)
for packets generated by the HWPing client to travel to and back from the destination
switch.
II. Network diagram
Figure 1-2
Network diagram for the ICMP test
III. Configuration procedure
z
Configure HWPing Client (Switch A):
# Enable HWPing client.
<Sysname> system-view
[Sysname] hwping-agent enable