Figure 2-2 Rack requirements
Cooling requirements
CAUTION:
•
For adequate heat dissipation, make sure the air inlet and outlet vents of the router are not
blocked and adequate clearance is reserved around the air vents.
•
Make sure the rack for the router has a good cooling system, with the perforation rate of rack
doors greater than 50%.
•
Make sure the air conditioners do not blow air directly onto the router.
The router uses super-short cut-through air aisles to provide front-to-rear airflow for heat dissipation,
as shown in