11-4
Figure 11-4 Connecting an E1 75-ohm cable (using coaxial connectors and 75-ohm
adapter cables)
•
If the impedance of the E1 port on the peer device is 120 ohms, you must use an impedance
converter to adapt the impedance.
Figure 11-5 Connecting an E1 75-ohm cable (using an impedance converter)
Routing signal cables
The cable management brackets are installed along the left and right edges of the front panel. As a
best practice, route signal cables along the cable management brackets as shown in
Coaxial connector
E1 75-ohm cable
E1 / E1-F
(75 ohm)
……
TX
RX
Peer device
(75-ohm E1 port)
TX
RX
75-ohm adapter cable
Impedance converter
E1 75-ohm cable
TX
RX
Straight-through network cable
Peer device
(120-ohm E1 port)
E1 / E1-F
(75 ohm)
……