6
4.
Crimp the RJ-45 connector with the crimping pliers until you hear a click.
5.
Repeat steps 2 to 5 to attach a connector to the other end of the cable.
Verifying the cable
Examine the assembled twisted pair connectors. If the cable cannot meet the following requirements,
reassemble the cable:
•
The connector surface must not contain obvious foreign objects, dirt or rust.
•
The wires must be extended to the front of the RJ-45 end as close as possible.
•
The end and front faces of the metal plating and the plastic spacer are not skewed or defective.
•
The wires are arranged in the correct sequence.
Use a cable tester to verify the connectivity of the cable:
1.
Insert the cable connectors into the RJ-45 female ports on the tester in turn.
2.
Gently shake the connectors of the twisted pair cable to confirm that the connectors are in
reliable contact with the RJ-45 female ports.
3.
Switch on the tester, and view the LEDs on the master and remote terminals.
For a straight-through cable, when master LEDs 1 through 8 and G are lighted in sequence,
the same-numbered LEDs on the remote terminal should be lighted.
For a crossover cable, when master LEDs 1 through 8 and G are lighted in sequence, the
LED lighting sequence on the remote terminal should be 3-6-1-4-5-2-7-8-G.
FigureB-11 Cable tester (straight-through network cable)
(1) Master terminal
(2) Remote terminal
1
2
Содержание CR16000-M
Страница 32: ...3 3 Figure3 2 Mounting the chassis on the slide rails 4 Attach the chassis to the rack with mounting screws...
Страница 75: ...9 6 Brief issue description Brief introduction of the troubleshooting procedures that have been taken...
Страница 88: ...12 FigureA 14 Example of a device label...
Страница 108: ...19 FigureB 35 Routing AC power cords...
Страница 116: ...12 6 Figure12 5 Repackaging the chassis...