![H3C CR16000-M Скачать руководство пользователя страница 34](http://html2.mh-extra.com/html/h3c/cr16000-m/cr16000-m_installation-manual_3061052034.webp)
3-5
The grounding cable provided with the router is compliant with the NEBS standards, with a
dual-hole grounding lug at one end for connecting to the chassis and a ring terminal at the other
end for connecting the grounding strip.
2.
As shown by callouts 1 and 2 in
remove the grounding screws from the grounding
holes at the rear of the chassis.
3.
As shown by callouts 3 and 4 in
use the grounding screws to attach the dual-hole
grounding lug of the grounding cable into the grounding holes of the chassis.
4.
As shown by callouts 5 and 6 in
connect the ring terminal of the grounding cable to a
grounding post on the grounding strip, and fasten the grounding cable to the grounding post
with the hex nut.
Figure3-4 Connecting the grounding cable to a grounding strip
Grounding the router through the PE wire of AC power
supplies
CAUTION:
Make sure the AC power supply uses a three-wire cable with a protection wire, and the PE wire of
the AC power supply is correctly grounded at the power distribution room or AC power supply
transformer side. In addition, make sure the PE terminal on the router is correctly connected to the
PE wire of the AC power supply.
If the router is AC powered and no grounding strip is available at the installation site, you can ground
the router through the PE wire of the AC power supply, as shown in
Содержание CR16000-M
Страница 32: ...3 3 Figure3 2 Mounting the chassis on the slide rails 4 Attach the chassis to the rack with mounting screws...
Страница 75: ...9 6 Brief issue description Brief introduction of the troubleshooting procedures that have been taken...
Страница 88: ...12 FigureA 14 Example of a device label...
Страница 108: ...19 FigureB 35 Routing AC power cords...
Страница 116: ...12 6 Figure12 5 Repackaging the chassis...