9-2
Flow control
—None.
Emulation
—VT100.
7.
If the issue persists, contract H3C support.
Garbled display on the configuration terminal
Symptom
The configuration terminal displays garbled text when the router is powered on.
Solution
To resolve the issue:
1.
Verify that the following settings are configured for the terminal:
Baud rate
—9600.
Data bits
—8.
Parity
—None.
Stop bits
—1.
Flow control
—None.
Emulation
—VT100.
2.
If the issue persists, contact H3C Support.
System failures during operation
Symptom
A system failure occurs when the router is operating.
Solution
To resolve the issue:
1.
Execute related commands to locate the fault.
2.
If a configuration error is found, re-configure the settings or restore the factory-default settings.
3.
If the issue persists, contact H3C Support.
Power supply failure
When a power supply is operating correctly, its status LEDs are green. For more information about
the status LEDs on power supplies, see
H3C CR16000-M Routers Hardware Information and
Specifications
.
Symptom
A status LED on a power supply is off or not green.
NOTE:
After a power supply is disconnected from its power source, it is normal that its LEDs stay on for
several seconds.
Solution
To resolve the issue:
Содержание CR16000-M
Страница 32: ...3 3 Figure3 2 Mounting the chassis on the slide rails 4 Attach the chassis to the rack with mounting screws...
Страница 75: ...9 6 Brief issue description Brief introduction of the troubleshooting procedures that have been taken...
Страница 88: ...12 FigureA 14 Example of a device label...
Страница 108: ...19 FigureB 35 Routing AC power cords...
Страница 116: ...12 6 Figure12 5 Repackaging the chassis...