background image

 

 

8

ACCESSORIES AND CONSUMABLES 
Accessories 

 
 
 
 
 
 
 
 

Consumables 

Regularly  check  the  wear  condition  of  the  protective  tip,  nozzle  and  electrode  or  in  case  of  significant  reduce  of  the 
cutting speed. 
It is advised to replace at the same time the nozzle and the electrode. 
 

 

 

Plasma 40FV 

Tip 

Replace if cracked or damaged 

040236 

Nozzle 

 

Clean if the inside of the nozzle is blocked or 
dirty. 
Replace if the opening is deformed or if the 
size of the orifice has half increased. 

040212 

Diffuser 

Replace if lateral orifices are bolcked. 

040175 

Electrode 

To replace: if  a significant cavity appears at 
the electrode center. 

040168 

 

 

 

TROUBLESHOOTING 

 

Anomalies 

Causes 

Remedies 

At startup, the display shows ’Er1’ 

The  device  was  turned  on  with  the 
trigger pressed 

Release the trigger 

At startup, the display shows ’Er2’ 

One  or  more  buttons  on  the  keypad  are 
pressed 

Release the button(s) 

At startup, the display shows ’- - -’ 

The  machine  is  connected  to  an 
unsuitable power supply (out of 85-265V 
range) 

Check the electrical system or generator 

In operation, the display shows ’- - -’ 

The overvoltage protection is active. 

The  machine  delivers  no  power  and  the 
indicator (3) is on 

The  thermal  protection  of  the  Plasma 
Cutter is active 

Wait until the end of the cooling phase 

The  machine  delivers  no  power  and  the 
indicator (4) is on 

The torch nozzle is not in place 

Turn off the machine, check and replace the 
consumables, turn on the machine 

The display shows ’no Air’ 

The air pressure is too low 

Check  that  the  air  supply  is  properly 
connected  to  the  machine,  adjust  the  air 
pressure 

The machine delivers no power and the display 
shows ‘Er3’ 

No  contact  between  the  electrode  and 
the nozzle 

Turn 

off 

the 

product, 

check 

the 

consummables,  check  the  electrode  retracts 
and returns easily. Try again. 

The machine delivers no power and the display 
shows ‘Er4’ 

The electrode cannot retract 

Turn  off  the  product,  make  sure  that  the 
electrode  can  retract  and  return  easily.  Try 
again 

The display shows ’Er5’ 

The cutting cycle has stopped abnormally 

Turn  off  the  product,  wait  until  the  error 
disappears,  try  again.  If  the  error  persists 
return the product for inspection 

Compass divider kit 

(ref. 

040205)

 

For  circular  cutting  up  to 
134 cm diameter. 
Provided  with  3  axes: 
magnetic,  with  center  pin, 
with thread 

 

Trolley 

(

Ref. 040199)

 

For a comfortable use and be 
at the advised height 
For  optimizing  the  cutting 
performances  and  increase 
the nozzles life-time. 

 

Содержание 40FV

Страница 1: ...73502 V1 10 07 2013 P 3 5 18 20 P 6 8 18 20 S 9 11 18 20 P 12 14 18 20 CT 15 18 18 20...

Страница 2: ...t Druckluftst rung LED Piloto defecto de aire 6 Mode mesure de la pression Air Pressure Measurement Mode Druckmessungs Modus Modo medida de la presi n 7 Mode tole grillag e Metal Mesh mode Gitterschne...

Страница 3: ...seau lectrique et au r seau d air comprim Au pr alable fixez sur le filtre r gulateur l embout de raccordement pneumatique adapt votre installation Allumer l appareil gr ce au commutateur situ l arri...

Страница 4: ...re propre degr de pollution 3 plat humidit et plus d un m tre de la pi ce d couper Ne pas utiliser sous la pluie ou la neige Choc lectrique Cet appareil ne doit tre utilis que sur une alimentation mon...

Страница 5: ...se V rifier que l air soit bien raccord au produit r gler la pression d air Le poste ne d livre pas de puissance et l afficheur indique Er3 Pas de contact entre l lectrode et la tuy re Eteindre le pro...

Страница 6: ...ahine Connect the unit to the electricity and air supply Turn on the power switch at the back of the machine Connect the earth clamp to a clear area of the workpiece Adjust the pressure Choose the she...

Страница 7: ...same means any people in the welding environment Rain steam The working environment must be clean degree of pollution 3 and protected humidity against rain Put the appliance on an even place and at le...

Страница 8: ...vers no power and the indicator 3 is on The thermal protection of the Plasma Cutter is active Wait until the end of the cooling phase The machine delivers no power and the indicator 4 is on The torch...

Страница 9: ...uckluftregler an Schalten Sie das Ger t mit dem Ein Aus Schalter ein der sich hinten am Ger t befindet Verbinden Sie die Masseklemme mit dem zu schneidenden Teil Stellen Sie den Druckluftregler ein W...

Страница 10: ...findliche Personen oder Helfer m ssen auf Gefahren hingewiesen und mit den n tigen Schutzmitteln ausger stet werden Umgebung Benutzen Sie das Ger t nur in sauberer und gegen N sseeinwirkung gesch tzte...

Страница 11: ...chutz des Ger tes wurde ausgel st Warten Sie bis sich das Ger t wieder abgek hlt hat Der Lichtbogen z ndet nicht und die Anzeigeleuchte 4 leuchtet Die Brenner D se ist entweder falsch montiert worden...

Страница 12: ...uilla de conexi n neumatica adecuada para su instalaci n Poner en marcha el equipo gracias al conmutador situado detr s del equipo Conectar la pinza de masa sobre la zona perfectamente pulida de la pi...

Страница 13: ...temente en una atm sfera limpia graduaci n de contaminaci n 3 vapor de agua de plano y a m s de un metro de la pieza a soldar humedad Utilizaci n prohibida con lluvia o nieve Choque el ctrico Este apa...

Страница 14: ...r 3 est encendido La protecci n t rmica del aparato se ha puesto en marcha Esperar el fin del tiempo de enfriamiento El equipo no libera potencia y la pantalla 4 est encendida La boquilla de la antorc...

Страница 15: ...15 PLASMA CUTTER 40FV 16 CEE 7 7 Flexible Voltage 85 265 50 60 I1eff A CEI 61000 3 12 2 Mode 8 2 2 2 o o 3 5 2 PSI 8 b p PSI o o no air 8 2...

Страница 16: ...16 EN60974 1 X 60974 1 40 C T cycle 10 min Plasma 40FV 230V Plasma 40FV 110V I max 36 40A 43 40A 60 T cycle 10 min 30 A 25 A 100 Tcycle 10 min 25 A 20 A 40 C 2 3 EN 169 EN 379 3 1 CEI IEC 62081...

Страница 17: ...17 Plasma 40FV 040236 040212 040175 040168 A Er1 Er2 85 265V 3 4 no Air Er3 Er4 Er5 040205 134 3 040199...

Страница 18: ...formidad est establecida por el respeto a las normas EN60974 1 de 2005 EN 50445 de 2008 EN 60974 10 de 2007 El marcado CE fue fijado en 2013 JBDC PLASMA CUTTER 40FV 2006 95 CE 12 12 2006 CE 2004 108 C...

Страница 19: ...ec risque accru de choc lectrique La source de courant elle m me ne doit toutefois pas tre plac e dans de tels locaux Adapted for cutting in environment with increased risks of electrical shock Howeve...

Страница 20: ...richt europ ischen Richtlinien El aparato est conforme a las normas europeas Conforme aux normes GOST Russie Conform to standards GOST PCT Russia in Ubereinstimmung mit der Norm GOST PCT Conforme a la...

Отзывы: