![GW Instek GPM-8310 Скачать руководство пользователя страница 208](http://html1.mh-extra.com/html/gw-instek/gpm-8310/gpm-8310_user-manual_2280059208.webp)
GPM-8310 User Manual
208
Description
Sets or returns the output components of the
harmonic measurement numeric list data.
Syntax
:NUMeric:LIST:SELect {EVEN|ODD|ALL}
Query Syntax
:NUMeric:LIST:SELect?
Parameter/
Return parameter
EVEN
Outputs the components of TOTal, DC, and
even-order harmonics.
ODD
Outputs the components of TOTal, DC, and
odd-order harmonics .
ALL
Outputs all components.
Example
:NUMERIC:LIST:SELECT ALL
:NUMERIC:LIST:SELECT?
->:NUMERIC:LIST:SELECT ALL
:NUMeric:LIST:ITEM<x>
Description
Sets or returns the output item (function and
element) of the specified harmonic measurement
numeric list data item.
Syntax
:NUMeric:LIST:ITEM<x>
{NONE|<Function>,<Element>}
Query Syntax
:NUMeric:LIST:ITEM<x>?
Parameter/
Return parameter
<x>
1 to 8 (item number)
NONE
No output item.
<Function>
{U|I|P|PHIU|PHII|UHDF|UHDF|PHDF
}
<Element>
1(If <Element> is omitted, the element
is set to 1)( For the GPM-8310, only set
to 1 or omitted)
Example
:NUMERIC:LIST:ITEM1 U,1
:NUMERIC:LIST:ITEM1?
->:NUMERIC:LIST:ITEM1 U,1
Set
Query
Содержание GPM-8310
Страница 1: ...Digital Power Meter GPM 8310 USER MANUAL Rev A ISO 9001 CERTIFIED MANUFACTURER ...
Страница 74: ...GPM 8310 User Manual 74 3 Press Config soft key to Enter SYSTEM CONFIG setting screen ...
Страница 135: ...DIGITAL I O DA4 135 Pin Diagram Use the built in power supply Use the external power Method of series ...
Страница 221: ...COMMAND OVERVIEW 221 Example STATUS QMESSAGE ON STATUS QMESSAGE STATUS QMESSAGE 1 ...
Страница 239: ...APPENDIX 239 Status system The diagram below is a description of the status system ...
Страница 243: ...APPENDIX 243 Dimensions Units mm ...