Example
:INPUT:CURRENT:AUTO ON
:INPUT:CURRENT:AUTO?
->:INPUT:CURRENT:AUTO 1
[:INPut]:CURRent:CONFig
Description
Sets or returns the valid current range.
Syntax
[:INPut]:CURRent:CONFig
{ALL|<Current>[,Current]…}
Query Syntax
[:INPut]:CURRent:CONFig?
Parameter/
Return parameter
ALL
All ranges are valid.
<Current> See(:INPut:CURRent:RANGe).
Example
:INPUT:CURRENT:CONFIG 20,10,1
:INPUT:CURRENT:CONFIG?
->:INPUT:CURRENT:CONFIG 20.0E+00,10.0E+00,
1.0E+00
[:INPut]:CURRent:POJump
Description
Sets or returns the jump destination range that is
used when a current peak over-range occurs.
Syntax
[:INPut]:CURRent:POJump {OFF|<Current>}
Query Syntax
[:INPut]:CURRent:POJump?
Parameter/
Return parameter
OFF
No jump destination current range.
<Current > See(:INPut:CURRent:RANGe).
Example
:INPUT:CURRENT:POJUMP 20A
:INPUT:CURRENT:POJUMP?
->:INPUT:CURRENT:POJUMP 20.0E+00