COMMAND OVERVIEW
185
Example
:INPUT:SYNCHRONIZE VOLTAGE
:INPUT:SYNCHRONIZE?
->:INPUT:SYNCHRONIZE VOLTAGE
[:INPut]:FILTer
Description
Returns all input filter settings.
Query Syntax
[:INPut]:FILTer?
Return parameter <String>
[:INPut]:FILTer:LINE
Description
Sets or returns the line filter.
Syntax
[:INPut]:FILTer:LINE {<Boolean>|OFF|ON}
Query Syntax
[:INPut]:FILTer:LINE?
Parameter
<Boolean>0 OFF
<Boolean>1 ON
Return parameter 0
Turn the line filter function off.
1
Turn the line filter function on.
Example
:INPUT:FILTER:LINE OFF
:INPUT:FILTER:LINE?
->:INPUT:FILTER:LINE 0
[:INPut]:FILTer:FREQuency
Description
Sets or returns the frequency filter.
Syntax
[:INPut]:FILTer:FREQuency {<Boolean>|OFF|ON}
Query Syntax
[:INPut]:FILTer:FREQuency?
Query
Set
Query
Set
Query