Table 8.1 Decimal, Hexadecimal and Decimal Conversion Table 

Dec 

Hex 

Binary 

 

Dec 

Hex 

Binary 

 

Dec 

Hex 

Binary 

 

Dec 

Hex 

Binary 

00 

00000000 

 

64 

40 

01000000 

 

128 

80 

10000000 

 

192 

CO 

11000000 

01 

00000001 

 

65 

41 

01000001 

 

129 

81 

10000001 

 

193 

C1 

11000001 

02 

00000010 

 

66 

42 

01000010 

 

130 

82 

10000010 

 

194 

C2 

11000010 

03 

00000011 

 

67 

43 

01000011 

 

131 

83 

10000011 

 

195 

C3 

11000011 

04 

00000100 

 

68 

44 

01000100 

 

132 

84 

10000100 

 

196 

C4 

11000100 

05 

00000101 

 

69 

45 

01000101 

 

133 

85 

10000101 

 

197 

C5 

11000101 

06 

00000110 

 

70 

46 

01000110 

 

134 

86 

10000110 

 

198 

C6 

11000110 

07 

00000111 

 

71 

47 

01000111 

 

135 

87 

10000111 

 

199 

C7 

11000111 

08 

00001000 

 

72 

48 

01001000 

 

136 

88 

10001000 

 

200 

C8 

11001000 

09 

00001001 

 

73 

49 

01001001 

 

137 

89 

10001001 

 

201 

C9 

11001001 

10 

0A 

00001010 

 

74 

4A 

01001010 

 

138 

8A 

10001010 

 

202 

CA 

11001010 

11 

OB 

00001011 

 

75 

4B 

01001011 

 

139 

8B 

10001011 

 

203 

CB 

11001011 

12 

OC 

00001100 

 

76 

4C 

01001100 

 

140 

8C 

10001100 

 

204 

CC 

11001100 

13 

0D 

00001101 

 

77 

4D 

01001101 

 

141 

9D 

10001101 

 

205 

CD 

11001101 

14 

0E 

00001110 

 

78 

4E 

01001110 

 

142 

8E 

10001110 

 

206 

CE 

11001110 

15 

OF 

00001111 

 

79 

4F 

01001111 

 

143 

8F 

10001111 

 

207 

CF 

11001111 

16 

10 

00010000 

 

80 

50 

01010000 

 

144 

90 

10010000 

 

208 

D0 

11010000 

17 

11 

00010001 

 

81 

51 

01010001 

 

145 

91 

10010001 

 

209 

D1 

11010001 

18 

12 

00010010 

 

82 

52 

01010010 

 

146 

92 

10010010 

 

210 

D2 

11010010 

19 

13 

00010011 

 

83 

53 

01010011 

 

147 

92 

10010011 

 

211 

D3 

11010011 

20 

14 

00010100 

 

84 

54 

01010100 

 

148 

94 

10010100 

 

212 

D4 

11010100 

21 

15 

00010101 

 

85 

55 

01010101 

 

149 

95 

10010101 

 

213 

D5 

11010101 

22 

16 

00010110 

 

86 

56 

01010110 

 

150 

96 

10010110 

 

214 

D6 

11010110 

23 

17 

00010111 

 

87 

57 

01010111 

 

151 

97 

10010111 

 

215 

D7 

11010111 

24 

18 

00011000 

 

88 

58 

01011000 

 

152 

98 

10011000 

 

216 

D8 

11011000 

25 

19 

00011001 

 

89 

59 

01011001 

 

153 

99 

10011001 

 

217 

D9 

11011001 

26 

1A 

00011010 

 

90 

5A 

01011010 

 

154 

9A 

10011010 

 

218 

DA 

11011010 

27 

1B 

00011011 

 

91 

5B 

01011011 

 

155 

9B 

10011011 

 

219 

DB 

11011011 

28 

1C 

00011100 

 

92 

5C 

01011100 

 

156 

9C 

10011100 

 

220 

DC 

11011100 

29 

1D 

00011101 

 

93 

5D 

01011101 

 

157 

9D 

10011101 

 

221 

DD 

11011101 

30 

1E 

00011110 

 

94 

5E 

01011110 

 

158 

9E 

10011110 

 

222 

DE 

11011110 

31 

1F 

00011111 

 

95 

5F 

01011111 

 

159 

9F 

10011111 

 

223 

DF 

11011111 

32 

20 

00100000 

 

96 

60 

01100000 

 

160 

A0 

10100000 

 

224 

EO 

11100000 

33 

21 

00100001 

 

97 

61 

01100001 

 

161 

A1 

10100001 

 

225 

E1 

11100001 

34 

22 

00100010 

 

98 

62 

01100010 

 

162 

A2 

10100010 

 

226 

E2 

11100010 

35 

23 

00100011 

 

99 

63 

01100011 

 

163 

A3 

10100011 

 

227 

E3 

11100011 

36 

24 

00100100 

 

100 

64 

01100100 

 

154 

A4 

10100100 

 

228 

E4 

11100100 

37 

25 

00100101 

 

101 

65 

01100101 

 

165 

A5 

10100101 

 

229 

E5 

11100101 

38 

26 

00100110 

 

102 

66 

01100110 

 

166 

A6 

10100110 

 

230 

E6 

11100110 

39 

27 

00100111 

 

103 

67 

01100111 

 

167 

A7 

10100111 

 

232 

E7 

11100111 

40 

28 

00101000 

 

104 

68 

01101000 

 

168 

A8 

10101000 

 

232 

E8 

11101000 

41 

29 

00101001 

 

105 

69 

01101001 

 

169 

A9 

10101001 

 

233 

E9 

11101001 

42 

2A 

00101010 

 

106 

6A 

01101010 

 

170 

AA 

10101010 

 

234 

EA 

11101010 

43 

2B 

00101011 

 

107 

6B 

01101011 

 

171 

AB 

10101011 

 

235 

EB 

11101011 

44 

2C 

00101100 

 

108 

6C 

01101100 

 

172 

AC 

10101100 

 

236 

EC 

11101100 

45 

2D 

00101101 

 

109 

6D 

01101101 

 

173 

AD 

10101101 

 

237 

ED 

11101101 

46 

2E 

00101110 

 

110 

6E 

01101110 

 

174 

AE 

10101110 

 

238 

EE 

11101110 

47 

2F 

00101111 

 

111 

6F 

01101111 

 

175 

AF 

10101111 

 

239 

EF 

11101111 

48 

30 

00110000 

 

112 

70 

01110000 

 

176 

B0 

10110000 

 

240 

F0 

11110000 

49 

31 

00110001 

 

113 

71 

01110001 

 

177 

B1 

10110001 

 

241 

F1 

11110001 

50 

32 

00110010 

 

114 

72 

01110010 

 

178 

B2 

10110010 

 

242 

F2 

11110010 

51 

33 

00110011 

 

115 

73 

01110011 

 

179 

B3 

10110011 

 

243 

F3 

11110011 

52 

34 

00110100 

 

116 

74 

01110100 

 

180 

B4 

10110100 

 

244 

F4 

11110100 

53 

35 

00110101 

 

117 

75 

01110101 

 

181 

B5 

10110101 

 

245 

F5 

11110101 

54 

36 

00110110 

 

118 

76 

01110110 

 

182 

B6 

10110110 

 

246 

F6 

11110110 

55 

37 

00110111 

 

119 

77 

01110111 

 

183 

B7 

10110111 

 

247 

F7 

11110111 

56 

38 

00111000 

 

120 

78 

01111000 

 

183 

B8 

10111000 

 

248 

F8 

11111000 

57 

39 

00111001 

 

121 

79 

01111001 

 

185 

B9 

10111001 

 

249 

F9 

11111001 

58 

3A 

00111010 

 

122 

7A 

01111010 

 

186 

BA 

10111010 

 

250 

FA 

11111010 

59 

3B 

00111011 

 

123 

7B 

01111011 

 

187 

BB 

10111011 

 

251 

FB 

11111011 

60 

3C 

00111100 

 

124 

7C 

01111100 

 

188 

BC 

10111100 

 

252 

FC 

11111100 

61 

3D 

00111101 

 

125 

7D 

01111101 

 

189 

BD 

10111101 

 

253 

FD 

11111101 

62 

3E 

00111110 

 

126 

7E 

01111110 

 

190 

BE 

10111110 

 

254 

FE 

11111110 

63 

3F 

00111111 

 

127 

7F 

01111111 

 

191 

BF 

10111111 

 

255 

FF 

11111111 

Содержание RotaSec B120D

Страница 1: ...CCEC OM Manuals RotaSec Titan 1 5 08 2009 This Manual Refers to the RotaSec fitted with the Titan Head RotaSec With Damping Installation Operation and Maintenance Manual...

Страница 2: ...CCEC OM Manuals RotaSec Titan 1 5 08 2009...

Страница 3: ...ol Devices 16 Programmable Parameters 16 SECTION 4 TECHNICAL INFORMATION 17 Standard Features 17 Optional Features 17 Typical Layout Details 18 Typical Titan Head Mechanism Elevation 23 Drives and Con...

Страница 4: ...ciples of Setting To Work Fig 5 21 and 5 22 58 Variations for R Models 59 Variations for S Models 59 Electrical Connections 78 Testing after Installation 79 SECTION 6 MAINTENANCE 86 General Care 86 Ro...

Страница 5: ...ctrical units are to be undertaken only by persons fully aware of the danger involved and who have taken adequate precautions and training Errors Reports on errors comments and suggestions concerning...

Страница 6: ...nt facts and conditions Static Sensitive Devices Some of the PCBs within in the equipment which is covered by this technical manual contain Static Sensitive Devices It is recommended that maintenance...

Страница 7: ...ting 2 General Installation Who is at Risk Site personnel Hazard Objects Tools in Installation area Current Controls Trained Installation Engineers Rating 4 General Maintenance Who is at Risk Site Per...

Страница 8: ...ry Low Voltage and EMC Directives With each unit a Declaration of Conformity is supplied Important Notice The Gunnebo RotaSec is a security product and as such any Children or Minors using the turnsti...

Страница 9: ...and cone bearing at the base On double units the rotors can be interlocked where space is of prime importance Entry and Exit can be made by Card reader Pushbutton or any other type of control device...

Страница 10: ...nels S120S Single Unit with canopy and side panels B90D Basic Double Unit open frame design without canopy B120D Basic Double Unit open frame design without canopy F90D Double Unit without canopy F120...

Страница 11: ...11 CCEC OM Manual RotaSec Titan 1 5 EN 08 2009 Typical Units Model B90S Model F90S...

Страница 12: ...12 CCEC OM Manual RotaSec Titan 1 5 EN 08 2009 Model R120S Model R120DI...

Страница 13: ...lock which prevents two passages at one time A self centring mechanism to ensure complete rotation of the head to the reset position A hydraulic damper to ensure smooth and quiet operation An anti bac...

Страница 14: ...ol logic with the following features Three inputs for sensor directing the mechanism position One input for opening locking the mechanism in each direction Two protected outputs for control of the ope...

Страница 15: ...the RotaSec in either direction 1 The Rotor will normally be locked unless a free entry exit option has been specified 2 Operate the Access Control Device if fitted 3 On the acceptance of a signal fro...

Страница 16: ...ble Parameters The system operation is conditioned by the values given to certain parameters stored in the LCM02 PCB When the control logic microprocessor executes the program it verifies the values o...

Страница 17: ...ard colours Walkway down lights not fitted on Basic Models Integral drain pipes only fitted to R and S Models Electro Mechanical head mechanism Rotor restoring mechanism Universal control logic Fail s...

Страница 18: ...eneral location of the main units assemblies that comprise the single RotaSec 90 Fig 4 1 Layout details RotaSec 90 Single Walkway Key to illustration A Rotor Head Mechanism B Electrical Plate Assembly...

Страница 19: ...neral location of the main units assemblies that comprise the single RotaSec 120 Fig 4 2 Layout details RotaSec 120 single walkway Key to illustration A Rotor Head Mechanism B Electrical Plate Assembl...

Страница 20: ...units assemblies that comprise the Double RotaSec 90 Fig 4 3 Layout details RotaSec 90 Double Walkway Key to illustration A Rotor Head Mechanism 1 B Rotor Head Mechanism 2 C Electrical Plate Assembly...

Страница 21: ...its assemblies that comprise the Double RotaSec 120 Fig 4 4 Layout details RotaSec 120 Double Walkway Key to illustration A Rotor Head Mechanism 1 B Rotor Head Mechanism 2 C Electrical Plate Assembly...

Страница 22: ...22 CCEC OM Manual RotaSec Titan 1 5 EN 08 2009 This section gives details of the main components that comprise a RotaSec Fig 4 5 90 O Titan Head Mechanism Fig 4 6 120 O Titan Head Mechanism...

Страница 23: ...1107 is available for this purpose Fine adjustment of the rotor home position in relation to the turnstile framework can be achieved by slackening the 4 x M12 mounting bolts in the slotted holes and r...

Страница 24: ...orce is always that required to rotate the unit to the next home position after the rotor has moved half way through the cycle following a release signal The length of the spring should be adjusted to...

Страница 25: ...is fairly critical and sensitive The restoring force can then be adjusted as in the previous section so that the rotor will return to the home position against the resistance of the damping Check this...

Страница 26: ...S1 output V01 for pass right anti clockwise rotation of the rotor When configured fail lock i e energise to release ideally the solenoids should be de energised to lock at the first sensor signal i e...

Страница 27: ...1 With solenoid de energised and plunger extended by action of the spring the locking pawl is held clear of the baffle plate outside diameter Adjust the position of solenoid coil if necessary with th...

Страница 28: ...ase clear of the baffle plate outside diameter De energise the solenoid and the pawl will re engage the ratchet block Electronic Circuit Boards Fig 4 12 Electrical Plate Assembly The mechanism has one...

Страница 29: ...OFF It displays the status of 14 inputs ON OFF OFF It allows the parameter programming SW2 It changes from parameter number parameter value Dot num parameter SW3 Decreases the displayed number SW4 Inc...

Страница 30: ...f two seven segment displays T1 and T2 and pushbuttons SW1 SW2 SW3 and SW4 Figure 4 13 Programming Pushbutton and Switch Locations Standard Jumper Settings JP 5 7 10 12 2 3 JP13 OFF JP14 OFF JP15 OFF...

Страница 31: ...tch between PARAMETER LOCATION and RELATIVE VALUE SW2 Location Value Pressing SW3 when a Location is displayed will move to a lower location SW3 Location Location Pressing SW3 when a Value is displaye...

Страница 32: ...TION IS DIFFERENT TO THOSE SET DURING FACTORY TESTING ANY CHANGES WILL DELETE THE ORIGINAL SETTINGS Parameter Default Setting The RotaSec always uses default 01 To select the default please follow thi...

Страница 33: ...is manual Sensor Board The board provides an interface between the Titan mechanism and the LCM02 Controller Logic Mounted on it are the position sensors for the rotary unit and all the connections req...

Страница 34: ...own on figure 5 27 29 Customer Connections section 5 Standard Jumper Settings JP1 On On On JP2 OFF JP3 NC JP4 NO JP5 Off On On JP6 NO JP7 NC JP8 Off M1 Alarms Y8 Pictograms A pin Description Pin Descr...

Страница 35: ...DL7 red On when aux alarm is activated DL8 yellow On when RL1 is activated It is fitted with two relays that provide ONE or ALL of the Alarms The Alarms are defined as follows Improper Transit Rotor P...

Страница 36: ...Loom Connections The solenoid connections can be configured on installation to match the head mechanisms configuration From Colour Pass Left Solenoid Common Black 24V F L Green 24V F S Orange Pass Ri...

Страница 37: ...ALLATION Site Preparation Ensure the site base area has been completed in accordance with the approved site installation drawing Reference to the Installation Figures Refer to Figs 5 1 to 5 20 should...

Страница 38: ...bility to ensure the structural integrity and strength of the installation location Bottom entry conduit location Stator bar dead area barrier Fixing locations Straight bar rotor Concrete of resistanc...

Страница 39: ...tomer s responsibility to ensure the structural integrity and strength of the installation location Bottom entry conduit location Stator bar dead area barrier Fixing locations Straight bar rotor Floor...

Страница 40: ...stomer s responsibility to ensure the structural integrity and strength of the installation location Bottom entry conduit location Stator bar dead area barrier Fixing locations Straight bar rotor Floo...

Страница 41: ...ure the structural integrity and strength of the installation location Bottom entry conduit location Stator bar dead area barrier Fixing locations Straight bar rotor Floor Anchors to be drilled during...

Страница 42: ...sure the structural integrity and strength of the installation location Bottom entry conduit location Stator bar dead area barrier Fixing locations Straight bar rotor Floor Anchors to be drilled durin...

Страница 43: ...structural integrity and strength of the installation location Bottom entry conduit location Stator bar dead area barrier Fixing locations Straight bar rotor Floor Anchors to be drilled during install...

Страница 44: ...structural integrity and strength of the installation location Bottom entry conduit location Fixing locations Straight bar rotor GRP canopy Walkway down light GRP side cabinet Stator bar dead area bar...

Страница 45: ...tomer s responsibility to ensure the structural integrity and strength of the installation location Stator bar dead area barrier Fixing locations Straight bar rotor Floor Anchors to be drilled during...

Страница 46: ...stomer s responsibility to ensure the structural integrity and strength of the installation location Floor Anchors to be drilled during installation 12mm dia x 100mm deep Concrete of resistance class...

Страница 47: ...stomer s responsibility to ensure the structural integrity and strength of the installation location Bottom entry conduit location Stator bar dead area barrier Fixing locations Straight bar rotor Floo...

Страница 48: ...is the customer s responsibility to ensure the structural integrity and strength of the installation location Concrete of resistance class at least fck cube 30 N mm2 Base to be flat and level to 5mm o...

Страница 49: ...ensure the structural integrity and strength of the installation location Fixing locations Floor Anchors to be drilled during installation 12mm dia x 100mm deep GRP canopy Walkway down lights Stator...

Страница 50: ...sponsibility to ensure the structural integrity and strength of the installation location Concrete of resistance class at least fck cube 30 N mm2 Base to be flat and level to 5mm over the SpeedStile f...

Страница 51: ...ensure the structural integrity and strength of the installation location Stator bar dead area barrier Straight bar rotor Floor Anchors to be drilled during installation 12mm dia x 100mm deep GRP can...

Страница 52: ...o ensure the structural integrity and strength of the installation location Concrete of resistance class at least fck cube 30 N mm2 Base to be flat and level to 5mm over the SpeedStile footprint area...

Страница 53: ...ep min per Unit IMPORTANT Any horizontal pipe or conduit runs below the RotaSec must be at least 140mm below FFL It is the customer s responsibility to ensure the structural integrity and strength of...

Страница 54: ...nsibility to ensure the structural integrity and strength of the installation location Concrete of resistance class at least fck cube 30 N mm2 Base to be flat and level to 5mm over the SpeedStile foot...

Страница 55: ...he structural integrity and strength of the installation location Fixing locations Straight bar rotor Floor Anchors to be drilled during installation 12mm dia x 100mm deep GRP canopy Walkway down ligh...

Страница 56: ...ensure the structural integrity and strength of the installation location Floor Anchors to be drilled during installation 12mm dia x 100mm deep Stator bar dead area barrier Concrete of resistance cla...

Страница 57: ...e conduit should be dedicated for the power supply from an external source and be run back to the nearest fused spur A triple core earthed 1 5mm 2 cable rated at a minimum of 10 amps should be provide...

Страница 58: ...ps 4 Assemble Items 6 and 7 ensuring that Item 6 is packed with grease and that the Bearing is Inserted in to the Bearing Cup 5 Fit and bolt together the items assembled in Step 1 and 2 using screws R...

Страница 59: ...etion of the Installation routines fit the Rain Water Down Pipe Cover by placing it in the hole provided in the GRP Roof Assembly Variations for S Models Omit Item No 2 of the Setting to Work Instruct...

Страница 60: ...60 CCEC OM Manual RotaSec Titan 1 5 EN 08 2009 Fig 5 22 Installation Model shown RotaSec F120S Fig 5 21 Installation Model shown RotaSec F90S...

Страница 61: ...61 CCEC OM Manual RotaSec Titan 1 5 EN 08 2009...

Страница 62: ...62 CCEC OM Manual RotaSec Titan 1 5 EN 08 2009 Fig 5 23 Frame Work installation details for the different Models Model B120S Basic Model F120S...

Страница 63: ...63 CCEC OM Manual RotaSec Titan 1 5 EN 08 2009 Model S90S Model R90S...

Страница 64: ...64 CCEC OM Manual RotaSec Titan 1 5 EN 08 2009 Model R120S Model S120S...

Страница 65: ...65 CCEC OM Manual RotaSec Titan 1 5 EN 08 2009 Model F90D...

Страница 66: ...66 CCEC OM Manual RotaSec Titan 1 5 EN 08 2009 Model F120D...

Страница 67: ...67 CCEC OM Manual RotaSec Titan 1 5 EN 08 2009 Model R90D...

Страница 68: ...68 CCEC OM Manual RotaSec Titan 1 5 EN 08 2009 Model R120D...

Страница 69: ...69 CCEC OM Manual RotaSec Titan 1 5 EN 08 2009 Model S90D...

Страница 70: ...70 CCEC OM Manual RotaSec Titan 1 5 EN 08 2009 Model S120D...

Страница 71: ...71 CCEC OM Manual RotaSec Titan 1 5 EN 08 2009 Model F90DI...

Страница 72: ...72 CCEC OM Manual RotaSec Titan 1 5 EN 08 2009 Model F120DI...

Страница 73: ...73 CCEC OM Manual RotaSec Titan 1 5 EN 08 2009 Model R90DI...

Страница 74: ...74 CCEC OM Manual RotaSec Titan 1 5 EN 08 2009 Model R120D...

Страница 75: ...75 CCEC OM Manual RotaSec Titan 1 5 EN 08 2009 Model S90DI...

Страница 76: ...76 CCEC OM Manual RotaSec Titan 1 5 EN 08 2009 Model S120DI...

Страница 77: ...77 CCEC OM Manual RotaSec Titan 1 5 EN 08 2009 Fig 5 24 Typical 90 O Rotor Assemblies Fig 5 25 Typical 120 O Rotor Assemblies...

Страница 78: ...Electrical Power Preparation Check the incoming mains supply is isolated Feed the mains supply cable through the RotaSec towards the MCB Cut back and strip the sleeving as shown in Fig 5 26 Remove th...

Страница 79: ...the following checks and tests be carried out Power Switch ON the mains power and the mains circuit breaker unit Mechanism Rotate the Rotor and check for parking position restoring and damping for a m...

Страница 80: ...entary signal Battery Back Up 24vDC Option From Power Supply Unit 24vDC Auxiliary DC Supply Locking Solenoids To Sensor PCB Traffic Status Lights 500mA typical 1A max Card Reader Reset 0v Card Reader...

Страница 81: ...nterface Connections Count signal Service Counter signal Audible Alarm 24vDC 40mA max 24v Supply Power Fail output 0v Emergency Fire Alarm 0v NC System Reset 0v momentary signal From LCM02 JP9 Passage...

Страница 82: ...82 CCEC OM Manual RotaSec Titan 1 5 EN 08 2009 Mains Power Supply 115 230vAC 50 60Hz Fig 5 29 Interface Connection Schematic Sensor PCB Controller PCB To Downlights Interface Connection PCB...

Страница 83: ...M Manual RotaSec Titan 1 5 EN 08 2009 Optional Equipment Figure 5 30 and 5 31 give details of how to install optional items i e Status Lights and Pushbuttons for the F and R model ranges Fig 5 30 Stat...

Страница 84: ...84 CCEC OM Manual RotaSec Titan 1 5 EN 08 2009 Fig 5 31 Optional Pushbuttons...

Страница 85: ...a single steel ball running in a housing Remember to insert the ball when the rotor column is fitted The bearing MUST be charged with the special grease supplied General Assembly Notes When all wiring...

Страница 86: ...ith soap and water rinse well with clean water and wipe dry Rust and other Corrosion products Stainless Finishes Cleaning agent Oxalic acid The cleaning solution should be applied with a swab and allo...

Страница 87: ...d before inspecting the mechanism Servicing Access All serviceable components can be accessed by the removal of all service hatches or from above the enclosure by removing the roof cover Ensure the se...

Страница 88: ...efitted Disconnect the power supplies Remove all connectors from the PCB If necessary remove the PCB supports and the small chip in Master side LCM02 Disconnect the flat cable from the UCM95 if the PC...

Страница 89: ...r cam of the rotary unit When the rotor is in the barrier position segment b should be illuminated Segments d and g also flash but these reproduce the signals generated by the internal logic of the LC...

Страница 90: ...eck all electrical wiring for security of connectors Check supply fuses are serviceable Check Mains input supply is correct Check fuses on LCM02 Card reader entrance device faulty Check 24v is present...

Страница 91: ...arts Code Description Qty SE LA MU 0007 Bulb 35W Clear 12V 2 SE FU MU 0013 Fuse Mains 24mm 3A 2 SE SO MU 0013 Locking Solenoid 1 SA DA MU 0003 Damper if fitted 1 SM SH MU 0037 Tension Pin M4 x 25 1 SM...

Страница 92: ...29 1D 00011101 93 5D 01011101 157 9D 10011101 221 DD 11011101 30 1E 00011110 94 5E 01011110 158 9E 10011110 222 DE 11011110 31 1F 00011111 95 5F 01011111 159 9F 10011111 223 DF 11011111 32 20 00100000...

Страница 93: ...e not engaged OE OF OF OF Riservato Reserved do not modify OF 14 14 14 PTOFineRot 1 100sec Magnet block time after a normal passage in unlock e single passage mode 10 14 14 14 PTODisinverso 1 10sec Op...

Страница 94: ...s Waiting dir A 0 Green 1 Red TABLE 4 PSetLettori Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 0 Accumulated credits 0 Not ordered 1 Order in a table 1 Reader resets alarms Only if PMaxPrenotaz 0 Number...

Страница 95: ...block time after a normal passage in unlock e single passage mode 10 14 14 14 PTODisInverso 1 10 sec Opposite direction blocking time 11 64 64 64 PTOPosiz 1 10 sec Position sensing timeout for arm ou...

Страница 96: ...Waiting dir A 0 Green 1 Red TABLE 4 PSetLettori Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 0 Accumulated credits 0 Not ordered 1 Order in a table 1 Reader resets alarms Only if PMaxPrenotaz 0 Number of...

Страница 97: ...97 CCEC OM Manuals RotaSec Titan 1 5 08 2009 Section 9 Declaration of Conformity Declaration of Conformity...

Страница 98: ...98 CCEC Product Data CCEC O M Manuals ClearSec 1 3 09 2008 Notes...

Страница 99: ...99 CCEC OM Manual RotaSec Titan 1 5 EN 08 2009 Notes...

Страница 100: ...K Tel 44 0 1825 761022 Fax 44 0 1825 763835 E mail info entrancecontrol gunnebo com Web www gunnebo com A COMPANY WITHIN THE GUNNEBO GROUP HEAD OFFICE SWEDEN Gunnebo AB Box 5181 SE 402 26 Goteborg SWE...

Отзывы: