Expert Power Control 8021/8025
© 2021 GUDE Systems GmbH
Specifications
ip4 dhcp enabled show
shows IPv4 DHCP state
3
ip6
enters cmd group "ip6"
ip6 enabled set {OFF=0|ON=1}
enables IPv6 on/off
ip6 enabled show
shows if IPv6 is enabled
3
ip6 routadv enabled set {OFF=0|ON=1}
enables IPv6 router advertisement
ip6 routadv enabled show
shows IPv6 router advertisement state
3
ip6 dhcp enabled set {OFF=0|ON=1}
enables IPv6 DHCP on/off
ip6 dhcp enabled show
shows if IPv6 DHCP is enabled
3
ip6 address show
show all IPv6 addresses
4
ip6 gateway show
show all IPv6 gateways
4
ip6 dns show
show all IPv6 DNS server
4
ip6 manual enabled set {OFF=0|ON=1}
enables manual IPv6 addresses
ip6 manual enabled show
shows if manual IPv6 addresses are enabled
3
ip6 manual address {1..4} set "{ip_address}"
sets manual IPv6 address
ip6 manual address {1..4} show
shows manual IPv6 address
3
ip6 manual gateway set "{ip_address}"
sets manual IPv6 gateway address
ip6 manual gateway show
shows manual IPv6 gateway address
3
ip6 manual dns {1..2} set "{ip_address}"
sets manual IPv6 DNS server address
ip6 manual dns {1..2} show
shows manual IPv6 DNS server address
3
ipacl
enters cmd group "ipacl"
ipacl ping enabled set {OFF=0|ON=1}
enables ICMP ping on/off
ipacl ping enabled show
shows if ICMP ping enabled
ipacl enabled set {OFF=0|ON=1}
enable IP filter on/off
ipacl enabled show
shows if IP filter enabled
ipacl filter {ipacl_num} set "{dns_name}"
sets IP filter {ipacl_num}
ipacl filter {ipacl_num} show
shows IP filter {ipacl_num}
linesensor
enters cmd group "linesensor"
linesensor all {field_list} show
shows energy sensors according field list of all line
sensors
5
linesensor {line_num} {field_list} show
shows energy sensors according field list of one
line sensor
5
linesensor {line_num} {energy_sensor} value showshows energy sensor of given line
5
linesensor {line_num} ovp show
show state of Overvoltage Protection
linesensor {line_num} counter reset
resets energy metering counter
linesensor {line_num} label set "{name}"
sets line meter to label
linesensor {line_num} label show
shows label of line meter
linesensor {line_num} {energy_sensor} events set
{OFF=0|ON=1}
enables events on/off
linesensor {line_num} {energy_sensor} events
show
shows if events are enabled
linesensor {line_num} {energy_sensor} events
type set
"{EVT_SYSLOG=0,EVT_SNMP=1,EVT_EMAIL=2
,EVT_SMS=3,EVT_GSMEMAIL=4,EVT_BEEPER
=5}"
enables different event types
linesensor {line_num} {energy_sensor} events
type show
shows what event types are enabled
linesensor {line_num} {energy_sensor} events
beeper mode set {CONTINOUS=0|
INTERMITTENT=1}
sets beeper tone
linesensor {line_num} {energy_sensor} events
beeper mode show
shows beeper tone
linesensor {line_num} {energy_sensor} maxval set
{float}
sets maximum value for line meter
linesensor {line_num} {energy_sensor} maxval
show
shows maximum value for line meter
linesensor {line_num} {energy_sensor} minval set
{float}
sets minimum value for line meter
linesensor {line_num} {energy_sensor} minval
show
shows minimum value for line meter
linesensor {line_num} {energy_sensor} hyst set
{float}
sets hysterese value for line meter
linesensor {line_num} {energy_sensor} hyst show shows hysterese value for line meter
linesensor {line_num} {energy_sensor} publish
mode set {NONE=0|INTERVAL=1|
DIFFERENCE=2}
sets publish mode
linesensor {line_num} {energy_sensor} publish
mode show
shows publish mode
linesensor {line_num} {energy_sensor} publish
trigger set {float}
sets trigger value for publish
linesensor {line_num} {energy_sensor} publish
trigger show
shows trigger value for publish
linesensor {line_num} {energy_sensor}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
sets Port for Power Port Switching actions