58
Expert Power Control 8021/8025
© 2021 GUDE Systems GmbH
Specifications
settable
Resettable Forward Reactive Energy counter.
epc8021RevEnergyActive
.77.1.5.1.2.1.20.x
Gauge32
RO
Reverse Active Energy counter.
epc8021RevEnergyReactive
.77.1.5.1.2.1.21.x
Gauge32
RO
Reverse Reactive Energy counter.
epc8021RevEnergyActiveReset-
table
.77.1.5.1.2.1.22.x
Gauge32
RO
Resettable Reverse Active Energy counter.
epc8021RevEnergyReactiveReset-
table
.77.1.5.1.2.1.23.x
Gauge32
RO
Resettable Reverse Reactive Energy counter.
epc8021ResidualCurrent
.77.1.5.1.2.1.24.x
Unsigned32
RO
Actual Residual Current on Power Channel. According Type A IEC
60755. Only visible on models that support this feature.
epc8021ResidualCurrentRMS
.77.1.5.1.2.1.25.x
Unsigned32
RO
Actual Residual Current RMS on Power Channel. According Type B IEC
60755. Only visible on models that support this feature.
epc8021ResidualCurrentDC
.77.1.5.1.2.1.26.x
Unsigned32
RO
Actual Residual Current DC on Power Channel. According Type B IEC
60755. Only visible on models that support this feature.
epc8021LineSensorName
.77.1.5.1.2.1.100.x
OCTETS
RW
A textual string containing name of a Line Sensor
epc8021OVPIndex
.77.1.5.2.1.1.x
Integer32
RO
None
epc8021OVPStatus
.77.1.5.2.1.2.x
INTEGER
RO
shows the status of the built-in Overvoltage Protection
epc8021CPUSensorVsystem
.77.1.5.14.1.0
Gauge32
RO
System Voltage on CPU Board
epc8021CPUSensorVaux
.77.1.5.14.2.0
Gauge32
RO
Auxiliary Voltage on CPU Board
epc8021CPUSensorVmain
.77.1.5.14.3.0
Gauge32
RO
Main Voltage on CPU Board
epc8021CPUSensorTcpu
.77.1.5.14.4.0
Integer32
RO
Temperature on CPU Board
epc8021NTPTimeValid
.77.1.5.15.1.0
INTEGER
RO
Show if valid Time is received
epc8021NTPUnixTime
.77.1.5.15.2.0
Unsigned32
RO
show received NTP time as unixtime (secs since 1 January 1970)
epc8021NTPLastValidTimestamp
.77.1.5.15.3.0
Unsigned32
RO
show seconds since last valid NTP timestamp received
epc8021SensorIndex
.77.1.6.1.1.1.x
Integer32
RO
None
epc8021TempSensor
.77.1.6.1.1.2.x
Integer32
RO
actual temperature
epc8021HygroSensor
.77.1.6.1.1.3.x
Integer32
RO
actual humidity
epc8021AirPressure
.77.1.6.1.1.5.x
Integer32
RO
actual air pressure
epc8021DewPoint
.77.1.6.1.1.6.x
Integer32
RO
dew point for actual temperature and humidity
epc8021DewPointDiff
.77.1.6.1.1.7.x
Integer32
RO
difference between dew point and actual temperature (Temp -
DewPoint)
epc8021ExtSensorName
.77.1.6.1.1.32.x
OCTETS
RW
A textual string containing name of a external Sensor
4.5.2
Device MIB 8025
Below is a table of all device-specific OID 's which can be accessed via SNMP. In the
numerical representation of the OID the prefix " 1.3.6.1.4.1.28507 " (Gude Enterprise
OID) was omitted at each entry in the table to preserve space. The example for a com-
plete OID would be "1.3.6.1.4.1.28507.79.1.1.1.1". A distinction is made in SNMP OID
's in between tables and scalars. OID scalar have the extension ".0" and only specify a
value. In SNMP tables the "x" is replaced by an index (1 or greater) to address a value
from the table.
Name
OID
Type
Acc.
Description
epc8025TrapCtrl
.79.1.1.1.1.0
Integer32
RW
Содержание Expert Power Control 8021 Series
Страница 2: ...2 Expert Power Control 8021 8025 2021 GUDE Systems GmbH...
Страница 5: ...Device Description...
Страница 14: ...Operating...
Страница 24: ...Configuration...
Страница 51: ...Specifications...
Страница 92: ...Support...