20
Step 2
Make sure the control box power switch is in the OFF position. The ON/OFF
Switch is located on the bottom of the control box. Remove the control box
cover and slide the battery into position with its terminals to the RIGHT (see
illustration). Connect the BLACK battery wire to the NEGATIVE (–) battery
terminal. Connect the RED battery wire to the POSITIVE (+) terminal. Pay
close attention to the color of the wires. If the wires are connected incorrectly,
the control board will be damaged. NEVER insert the battery with the
terminals to the left.
Mounting the Control Box
Step 3
Strip approximately 3/16" of insulation from each wire of the power cable. Twist
each exposed wire tightly (there are seven [7] wires inside the power cable sheath).
Loosen sealing nut on strain relief hub at bottom of control box. Insert power cable
into control box through strain relief. Thread approximately 6" of the power cable
into the control box and retighten sealing nut until the power cable locks into place.
Step 1
Mount the control box using the screws (provided) or another
secure mounting method. The control box must be mounted
at least 3 feet above the ground to protect it from rain
splash, snow, etc., and at least 3 feet from an AC power
source to prevent electrical interference.
RED wire to POSITIVE (
+
) terminal
BLACK wire to NEGATIVE (
—
) terminal
RED
BLACK
Sealing Nut
Hub
Lock Nut
Strain Relief
NOTE:
The battery that came
with your GTO/PRO® 4000/4200,
MUST be placed in the top
(horizontal) battery slot with the
terminals on the RIGHT. The
extra (vertical) battery slot is for
an optional second battery. An
optional second battery can be
used for solar and/or high traffic
applications, if needed..
Use mounting
holes and screws
provided to mount
control box to a
secure surface.
1
ON
2
3
4
5
6
7
1
ON
2
3
4
15
18VAC
RECEIVER
BAT+
SWITCH
FUSE
ALARM
SWITCH
DUAL
MODES
SET
LIMIT
LEARN
TRANSMITTER
MODES
ON
OFF
ON
OFF
1 2 3 4 5 6 7
1 2 3 4
BAT–
SOLAR
RELAY OUT
SLAVE INPUTS
GRN WHT BLUE
BRN ORG
RED
BLK
NC RLY-COM NO
MASTER INPUTS
GRN WHT BLUE
BRN ORG
RED
BLK
COM COM
CYCLE CLOSE
SAFETY
EXIT/ OPEN
SHADOW LOOP
CLOSE EDGE
OPEN EDGE
BLK
GRN
RED
+
–
~
~
12'
10'
8'
14'
16'
GATE LENGTH
800-543-GATE
www.gtoinc.com
GTO, Inc.
3121 Hartsfield Rd
Tallahassee, FL 32303
Operator Power Cable
12 V Battery (Included)
Strain Relief
1
ON
2
3
4
5
6
7
1
ON
2
3
4
15
18VAC
RECEIVER
BAT+
SWITCH
FUSE
ALARM
SWITCH
DUAL
MODES
SET
LIMIT
LEARN
TRANSMITTER
MODES
ON
OFF
ON
OFF
1 2 3 4 5 6 7
1 2 3 4
BAT–
SOLAR
RELAY OUT
SLAVE INPUTS
GRN WHT BLUE
BRN ORG
RED
BLK
NC RLY-COM NO
MASTER INPUTS
GRN WHT BLUE
BRN ORG
RED
BLK
COM COM
CYCLE CLOSE
SAFETY
EXIT/ OPEN
SHADOW LOOP
CLOSE EDGE
OPEN EDGE
BLK
GRN
RED
+
–
~
~
12'
10'
8'
14'
16'
GATE LENGTH
800-543-GATE
www.gtoinc.com
GTO, Inc.
3121 Hartsfield Rd
Tallahassee, FL 32303
Single Battery
Installed Horizontally
with terminals on the right.
Dual Batteries
Installed Vertically
with terminals on bottom.
Connecting Operator Power Cables