WARNING!

This equipment is similar to other gate or door equipment and meets or exceeds 

Underwriters Laboratory Standard 325 (UL 325). However, gate equipment has 

hazards associated with its use and therefore by installing this product the installer 

and user accept full responsibility for following and noting the installation and 

safety instructions. Failure to follow installation and safety instructions can result 

in hazards developing due to improper assembly. You agree to properly install this 

product and that if you fail to do so GTO Access Systems, (“GTO”) shall in no event 

be liable for direct, indirect, incidental, special or consequential damages or loss of 

profits whether based in contract tort or any other legal theory during the course 

of the warranty or at any time thereafter. The installer and/or user agree to assume 

responsibility for all liability and use of this product releasing GTO Access Systems, 

from any and all liability. If you are not in agreement with this disclaimer or do not 

feel capable of properly following all installation and safety instructions you may 

return this product for full replacement value.
READ ALL INSTRUCTIONS CAREFULLY AND COMPLETELY before attempting to 

install and use this automatic gate operator. This gate operator produces a high level 

of force. Stay clear of the unit while it is operating and exercise caution at all times.
All automatic gate operators are intended for use on 

vehicular gates only.

This product meets and exceeds the requirements of UL 325, the standard which 

regulates gate operator safety, by Underwriters Laboratories Inc.

For more information on the GTO ACCESS SYSTEMS full line of automatic gate 

operators and access controls visit our website at www.linearproaccess.com.

©2015 GTO Access Systems, LLC 

Printed in China for GTO Access Systems, LLC. 

R4818  06-03-16

DUAL Gate Operator System

Installation Manual

3000XLS

3000XLS

PROFESSIONAL RESIDENTIAL

ACCESS

SYSTEMS

3200XLS

3200XLS

PROFESSIONAL RESIDENTIAL

ACCESS

SYSTEMS

In a DUAL gate system the LPA 3000XLS is the MASTER gate 

operator and the LPA 3200XLS is the SECOND gate operator. 

PROFESSIONAL INSTALLATION RECOMMENDED!

NCB

Содержание 3000XLS

Страница 1: ...ith this disclaimer or do not feel capable of properly following all installation and safety instructions you may return this product for full replacement value READ ALL INSTRUCTIONS CAREFULLY AND COM...

Страница 2: ...stricted Access Vehicular Gate Operator Class IV A vehicular gate operator or system intended for use in a guarded industrial location or building such as an airport security area or other restricted...

Страница 3: ...e Bracket 10 Attach Operator 10 Install the Second Gate Operator 11 Install the Closed Position Stops 11 Mount Battery Box and Control Box 13 Connect Battery 13 Connect Operator Power Cables 15 Connec...

Страница 4: ...erators feature adjustable stall force This safety feature makes the gates stop and reverse direction within two seconds when it comes in contact with an obstruction The MIN setting means the gate wil...

Страница 5: ...s manual are identified with this warning symbol The symbol identifies conditions that can result in damage to the operator or its components serious injury or death Because GTO automatic gate operato...

Страница 6: ...alled and swings freely in both directions Repair or replace all worn or damaged gate hardware prior to installation A freely moving gate will require less force to operate and will enhance the perfor...

Страница 7: ...ach the warning signs included to each side of the gate to alert the public of auto matic gate operation It is your responsibility to post warning signs on both sides of your gate If any of these sign...

Страница 8: ...ess Systems at 3121 Hartsfield Road Tallahassee Florida 32303 or by calling 1 800 543 4283 and requesting a duplicate copy One will be provided to you free of charge Required Safety Precautions for Ga...

Страница 9: ...B A hard wired contact sensor shall be located and its wiring arranged so that the communication between the sensor and the gate operator is not subjected to mechanical damage C A wireless contact sen...

Страница 10: ...using Conforms to UL STD 325 Certified to CSA STD C22 2 No 247 Maximum Gate 650 lb 294 8 kg 16 ft 4 9 m Voltage 12 Vdc Frequency 0 Hz Power 60 W Class I II Vehicular Swing Gate Operator 3000XLS SERIES...

Страница 11: ...nting point to mounting point arm stroke 16 max Minimum gate length is 5 ft Adjustable auto close 3 to 120 seconds and stall force potentiometers Power terminal block accommodates a transformer or sol...

Страница 12: ...battery FM123 Refer to the Solar Panel and Gate Activity chart below All low voltage wire used with the GTO Gate Operator must be 16 gauge dual conductor stranded direct burial wire RB509 Do not run m...

Страница 13: ...zontal Cross Member Vertical Cross Member Your Property Your Property Pull To Open arm retracts to open Push To Open arm extends to open 3 Prepare the Gates The gate must be plumb level and swing free...

Страница 14: ...Cable GTO Transmitter 1 RB741 Master Gate Operator 1 LPA 3000XLS Arm BRACKET BOX HB301 CONTROL BOX AND ELECTRICAL COMPONENTS HARDWARE BAG H301P Control Box 1 Receiver 1 Hairpin Clip 2 3 8 x 2 1 2 Clev...

Страница 15: ...gns 2 Second Gate Operator 1 LPA 3200XLS Arm 40 Power Cable BRACKET BOX HB301 HARDWARE BAG H301P Hairpin Clip 2 3 8 x 2 1 2 Clevis Pin 1 1 2 x 2 3 4 Bolt 2 3 8 x 3 Bolt 2 3 8 x 8 Bolt 4 8 Nylon Cable...

Страница 16: ...lts Page 11 Surge protection for transformer Page 18 Weatherproof cover for transformer if installed outside Page 18 For push to open applications you must have two 2 PTO Brackets R4388 Drill Bit Dril...

Страница 17: ...necessary to use hex head bolts longer than those supplied Round wood posts no smaller than 8 diameter may be notched to create a flat surface for attaching the post bracket Wood posts will require a...

Страница 18: ...he position of post bracket holes on the post Step 3 Drill holes through post as marked using a 3 8 drill bit Install the post bracket using the 3 8 x 8 hex head bolts and 3 8 flat washers lock washer...

Страница 19: ...est part of the operator arm and the gate When you have achieved the best position for the post pivot bracket in the open position insert the 3 8 x 3 bolt and 3 8 flat washer through the aligned holes...

Страница 20: ...ke sure the gate bracket is clamped securely Install Gate Bracket Step 9 Detach the front mount from the gate bracket Check that the gate bracket holes are centered over the scribe line Mark the gate...

Страница 21: ...OND Gate Frame MASTER Gate Frame TOP VIEW FRONT VIEW Step 1 Detach the gate operators from the gates and move the gates to their closed position Illustration A Using appropriate hardware for your type...

Страница 22: ...plate The ground stop needs to be positioned near the end of the gate as shown in Illustration A and may be made of metal or concrete and should be firmly secured in the ground we recommend setting i...

Страница 23: ...he KNOCK OUT in the back of the CONTROL BOX Plug the BATTERY HARNESS wires into the wires coming from the CONTROL BOX Connecting the Battery Step 3 Slide the battery into position with the terminals t...

Страница 24: ...rent locations before permanently mounting the receiver The receiver range can vary from 50 to 100 feet depending upon weather topography and external interference Mount the receiver Ensuring a line o...

Страница 25: ...Cut a slot into the driveway to accommodate 3 4 PVC conduit not provided The buried conduit will protect the SECOND operator power cable from automobile tires lawn mower blades weed eaters and grazin...

Страница 26: ...GRN terminal the white wire into WHT the blue wire into BLUE brown wire into BRN orange wire into ORG red wire into RED and the black wire into the BLK terminal Tighten the set screws against the end...

Страница 27: ...rom an AC power source you will need to use at least 10 watts solar charging power FM122 FM123 to charge the battery Refer to the Solar Panels and Gate Activity Chart on page 2 Step 1 Make sure the co...

Страница 28: ...screws against exposed end of wires Step 6 At the transformer strip 1 2 of insulation from the ends of the low voltage wire Twist tightly and attach wires to the transformer terminals Make sure the ex...

Страница 29: ...old LEARN MAST LIMIT for 5 seconds or until buzzer beeps to set closed postion B If the second gate reaches closed postion first press and hold LEARN 2ND LIMIT for 5 seconds or until buzzer beeps to s...

Страница 30: ...w programmed Control Box Learn Master Limit Button 1 2 3 4 ON DIP STATUS LEARN RMT LEARN MAST LIMIT LEARN 2ND LIMIT S3 S4 S2 SOFT START OFF WARNING OFF OPEN PULL SLV OPEN DLY MODE1 OFF MODE2 OFF ON ON...

Страница 31: ...to increase the stall force in cold temperatures due to increased resistance from gate hinges Set Auto Close Time The Auto Close Time potentiometer controls the Auto Close feature and determines how...

Страница 32: ...close the access cover WARNING No other adjustments should be made inside the transmitter Step 3 Program the new setting into the control board A Press and hold transmitter button B Press and hold th...

Страница 33: ...the obstruction warning DIP Switch 3 Push Pull to Open ON Push to open OFF Pull to open factory preset If your gate opens into the property the DIP Switch is set to the OFF position factory setting I...

Страница 34: ...this input while at open limit will restart the auto close time if enabled Activation of this input while gate is idle will prevent gate from closing 5 SHADOW LOOP Typically for use with loop detecto...

Страница 35: ...ONTROL INPUTS CLOSE EDGE 2 3 4 5 6 7 WHT BLU BRN ORG RED BLK GRN WHT BLU BRN ORG RED BLK GRN COM CYCLE COM LOCK PWR AUX RLY POWER INPUT CONTROL OUTPUTS MASTER OPERATOR 2ND OPERATOR CONTROL INPUTS GTO...

Страница 36: ...sh to Open Post Pivot Bracket R4388 in the Post Bracket assembly B 4 IMPORTANT While determining the mounting point for the post pivot bracket assembly be sure that the position allows for 2 clearance...

Страница 37: ...Box Master Gate Operator Second Gate Operator Step 2 Press the transmitter to activate operator arms The gates will begin to open Gates Opening Control Box Step 3 When either gate reaches OPEN positi...

Страница 38: ...tivate operator arms The gates will begin to OPEN Step 6 The gate that was programmed in step 4 will stop on its own Press the transmitter again to stop the other gate when it reaches the desired OPEN...

Страница 39: ...Counter 1 beep with 10 seconds off Low Battery Condition Fuses Battery Harness Connections Battery Under Load 1 beep then 2 beeps Master Motor Terminals Shorted Connections to Master Inputs Master Ar...

Страница 40: ...accessory Status clear 5 blinks Close Edge Terminal Shorted Disconnect the edge sensor photo beam or any other accessory wired to this terminal Try the remote If the remote works the problem is the ac...

Страница 41: ...ired to send in your original equipment for repair Please refer to Manufactures Limited Warranty for complete details Securely pack the component s authorized for return to the factory Include a copy...

Страница 42: ...B741 RB742 RB743 Purchase an additional transmitter for each vehicle in your family The Two Button Transmitter can be programmed to operate both your gate operator and a garage door opener using the U...

Страница 43: ...property 100 ft range between transmitter and receiver Easy installation LOCKING SECURITY ACCESSORIES Automatic Gate Lock FM144 FM142 The 1 Accessory For Swing Gate Operators Designed for added securi...

Страница 44: ...rge Gate Grounding Kit R4196 The purpose of the grounding kit is to REDUCE THE RISK of damage to electronic equipment from lightning strikes There is no protection or grounding system that can complet...