background image

9

Parameter Display (14)

The control panel is equipped with a 

parameter display meter that shows voltage, 

frequency and hour run time. Press the 

mode change button (13) on the meter to 

cycle through each value. 

The meter functions are as follows:
- Output voltage in volts (V)
- Output current in amps (A)
- Output power in watts (P)
- Output frequency in hertz (Hz)
- Total operating hours (H)

LED Indicators

The LED Indicators assist in communicating 

proper and improper functions of the unit.

Low Oil Alarm (12)

When the engine oil falls below the required 

level the Low Oil Alarm will come on and the 

engine will stop automatically. The engine will 

not restart until oil is added to the unit to bring 

it up to the appropriate level.

Output Indicator (11)

The AC Output Indicator (pilot light) comes 

on when the engine starts and produces 

power.

Overload Alarm (10)

The Overload Alarm comes on when a con-

nected device requires more power than the 

generator is able to produce, the inverter con-

trol unit overheats, or the AC output voltage 

rises above rated values. The Output Indica-

tor (Green) will go off and the Overload Alarm 

(Red) will stay on, but the engine will continue 

to run.

When the Overload Alarm light comes on and 

power generation stops, proceed as follows:
1. Turn off any connected electric devices  

and stop the engine.

2.  Reduce the total wattage of connected  

electric devices within the rated output.

3.  Check for blockages in the cooling air inlet 

and around the control unit. If any block-

ages are found remove them.

4.  After checking, restart the engine.

NOTE: The Overload Alarm may come 

on for a few seconds when first using 

CAUTION!

Generator should only be operated on 

a level surface. DO NOT operate the 

generator on loose ground or obvious 

inclines. The low oil shutdown feature 

may be prematurely activated in these 

cases causing the engine to not start.

Side Pilot Columns (15)

The side pilot columns are general load 

indicators, showing an approximate load 

used by the generator with respect to the 

total rated power.

Control Functions

10

14

electrical devices that require a large 

starting current, such as a compres-

sor, pump, or refrigerator. This is nor-

mal behaviour it is not a malfunction.

13

11

12

15

Содержание GT3800Ei

Страница 1: ......

Страница 2: ...Product 3 Description of Symbols 3 Specifications 3 Safety Rules 4 Unpacking the Generator 6 Features and Controls 7 Control Functions 9 Preparation Before Operating 11 Calculating Your Power Needs 1...

Страница 3: ...orted taken to the local recycling centre and disposed of in an environmentally safe way Scope Of Product This product is suited for home and camping back up power rural and commercial applications De...

Страница 4: ...xhaust gas away from entering a confined area through windows doors ventilation intakes or other openings NEVER operate this product inside any building carport porch mobile equipment marine applicati...

Страница 5: ...fault circuit interrupter in any damp or highly conductive area such as metal decking or steel work DO NOT touch bare wires or receptacles DO NOT use generator with electrical cords which are worn fra...

Страница 6: ...e caught in the starter or other rotating parts Tie up long hair and remove jewellery DO NOT modify generator in any way NOTE Exceeding generators wattage amperage capacity could damage generator and...

Страница 7: ...strations with your generator to familiarise yourself with the locations of various controls and adjustments Save this manual for future reference 1 Fuel Cap 2 Fuel Level Indicator 3 Fuel Tank 4 Carry...

Страница 8: ...AC Breaker 6 2 x USB Ports 7 Ground Terminal 8 Eco Mode Switch 9 Start Stop Switch 1 2 3 4 5 6 9 8 10 Overload Alarm 11 Output Indicator 12 Low Oil Alarm 13 Parameter Reset Button 14 Parameter Display...

Страница 9: ...C output voltage rises above rated values The Output Indica tor Green will go off and the Overload Alarm Red will stay on but the engine will continue to run When the Overload Alarm light comes on and...

Страница 10: ...tec Service Provider according to the connected electrical load The results are better fuel consumption and less noise When the switch is in the OFF position the engine runs at 3600rpm regardless of w...

Страница 11: ...lames pilot lights heat and other ignition sources DO NOT light a cigarette or smoke when filling the fuel tank Fuel is highly FLAMMABLE and its vapours are EXPLOSIVE NOTE The battery supplied is NOT...

Страница 12: ...engine or carburetor cleaner products in the fuel tank as permanent damage may occur Remove the fuel cap turning counter clockwise Fill the tank with regular unleaded gaso line without exceeding the...

Страница 13: ...TU 3800 5000 32 000 BTU 5000 6500 Room Air Conditioner 10 000 BTU 1500 2200 Circular Saw 7 1 4 1400 2300 Chainsaw 2HP 1100 2500 Portable Air Compressor 1200 3600 Hand Drill 1 2 600 900 Drill 1 2 600 9...

Страница 14: ...e unit is in a level position Turn choke to ON position NOTE It may not be necessary to use the choke if the engine has been shut down and is warm NOTE If engine does not start up within 3 to 4 second...

Страница 15: ...ance is felt and then pull rapidly to avoid kickback Never start or stop engine with electrical devices plugged in and turned on If engine fails to start after 3 pulls or if unit shut down during oper...

Страница 16: ...top the engine with electrical devices plugged in and turned on Let engine run at no load for several minutes to stabilise the internal temperatures of engine and generator Move ON OFF switch to OFF p...

Страница 17: ...are visible on its exterior surface CAUTION Never insert any object or tool through the air cooling slots even if the engine is not running Items should be maintained and repaired by an Authorized Pow...

Страница 18: ...not operate engine in a poorly ven tilated room or other enclosed area Be sure to keep good ventilation in working area The exhaust from engine may contain poisonous CO inhalation can cause shock unc...

Страница 19: ...ke out the filter element B Clean the filter in a soap and water solu tion E Allow it to dry completely Dip the dry filter in oil F the same type as used in the generator engine Squeeze out excess oil...

Страница 20: ...he fixing screws Clean carbon deposits carefully with a brush Re install the spark arrester Transportation Storage Transportation In order to avoid fuel spillage during transportation always keep the...

Страница 21: ...ew again Remove the spark plug see page 19 for more info on removing spark plug Pour 1 tablespoon of clean motor oil 10 20ml in the cylinder Pull recoil handle gently this will mnake the engine spin a...

Страница 22: ...ct warranty serious personal injury property damage or even death If possible store the unit indoors and cover it to give protection from dust and dirt BE SURE TO EMPTY THE FUEL TANK If it is not prac...

Страница 23: ...mstances such as contaminated fuel or poor water supply modifica tions to the product attempted repair service by a party other than an Approved Service Agent is not covered under warranty Warranty do...

Страница 24: ...customer and will strive to provide you with the best service and reliability in the industry This product is backed by our extensive warranty and world wide service network Please contact your local...

Отзывы: