9
Parameter Display (14)
The control panel is equipped with a
parameter display meter that shows voltage,
frequency and hour run time. Press the
mode change button (13) on the meter to
cycle through each value.
The meter functions are as follows:
- Output voltage in volts (V)
- Output current in amps (A)
- Output power in watts (P)
- Output frequency in hertz (Hz)
- Total operating hours (H)
LED Indicators
The LED Indicators assist in communicating
proper and improper functions of the unit.
Low Oil Alarm (12)
When the engine oil falls below the required
level the Low Oil Alarm will come on and the
engine will stop automatically. The engine will
not restart until oil is added to the unit to bring
it up to the appropriate level.
Output Indicator (11)
The AC Output Indicator (pilot light) comes
on when the engine starts and produces
power.
Overload Alarm (10)
The Overload Alarm comes on when a con-
nected device requires more power than the
generator is able to produce, the inverter con-
trol unit overheats, or the AC output voltage
rises above rated values. The Output Indica-
tor (Green) will go off and the Overload Alarm
(Red) will stay on, but the engine will continue
to run.
When the Overload Alarm light comes on and
power generation stops, proceed as follows:
1. Turn off any connected electric devices
and stop the engine.
2. Reduce the total wattage of connected
electric devices within the rated output.
3. Check for blockages in the cooling air inlet
and around the control unit. If any block-
ages are found remove them.
4. After checking, restart the engine.
NOTE: The Overload Alarm may come
on for a few seconds when first using
CAUTION!
Generator should only be operated on
a level surface. DO NOT operate the
generator on loose ground or obvious
inclines. The low oil shutdown feature
may be prematurely activated in these
cases causing the engine to not start.
Side Pilot Columns (15)
The side pilot columns are general load
indicators, showing an approximate load
used by the generator with respect to the
total rated power.
Control Functions
10
14
electrical devices that require a large
starting current, such as a compres-
sor, pump, or refrigerator. This is nor-
mal behaviour it is not a malfunction.
13
11
12
15
Содержание GT3800Ei