10

Generator Ground / Earth 

Circuit (7)

The Earth terminal is used to earth the gen-

erator when earthed electrical devices are 

being used. Consult an electrician for local 

earthing regulations.

AC (3) and DC (5) Reset 

Circuit Breakers)

The Circuit Breakers turn the generator 

“OFF” automatically when an electrical de-

vice connected to the generator is operating 

above the rated current. To use this equip-

ment again, turn on the Circuit Breaker by 

pressing in its button to “ON”. If Circuit Break-

er cuts power out again, reduce the load of 

the connected electric device below the 

specified  rated  output  of  the  generator  and 

press button in to “ON” again. 

3

5

NOTE:

 

If the Circuit Breaker continues 

to cut out, stop using the device imme-

diately and consult your local author-

ised Powertec Service Provider.

according to the connected electrical load. 

The results are better fuel consumption and 

less noise. 

When the switch is in the “OFF” position the 

engine runs at 3600rpm regardless of wheth-

er there is a load connected or not.

NOTE:  The ECO switch must be 

turned to “OFF” when using electrical 

devices that require a large starting 

current, such as a compressor or a 

submergible pump.

ECO Mode Switch (8)

When the ECO switch is in the “ON” position 

the smart throttle controls the engine speed

8

USB Outlet (6)

The USB outlet is used to power and charge 

anything with a USB plug, such as phones, 

media players and other 5V DC devices.

7

6

NOTE:  Remember that many types 

of equipment need extra consump-

tion for start up. Equipment that uses 

an engine such as compressors, wa-

ter pumps, circular saws etc. can con-

sume up to 3 times more power for 

start up. For example a 1000W water 

pump will need 3000W to start up, 

therefore a generator 3000W or more 

would be required.

Содержание GT3800Ei

Страница 1: ......

Страница 2: ...Product 3 Description of Symbols 3 Specifications 3 Safety Rules 4 Unpacking the Generator 6 Features and Controls 7 Control Functions 9 Preparation Before Operating 11 Calculating Your Power Needs 1...

Страница 3: ...orted taken to the local recycling centre and disposed of in an environmentally safe way Scope Of Product This product is suited for home and camping back up power rural and commercial applications De...

Страница 4: ...xhaust gas away from entering a confined area through windows doors ventilation intakes or other openings NEVER operate this product inside any building carport porch mobile equipment marine applicati...

Страница 5: ...fault circuit interrupter in any damp or highly conductive area such as metal decking or steel work DO NOT touch bare wires or receptacles DO NOT use generator with electrical cords which are worn fra...

Страница 6: ...e caught in the starter or other rotating parts Tie up long hair and remove jewellery DO NOT modify generator in any way NOTE Exceeding generators wattage amperage capacity could damage generator and...

Страница 7: ...strations with your generator to familiarise yourself with the locations of various controls and adjustments Save this manual for future reference 1 Fuel Cap 2 Fuel Level Indicator 3 Fuel Tank 4 Carry...

Страница 8: ...AC Breaker 6 2 x USB Ports 7 Ground Terminal 8 Eco Mode Switch 9 Start Stop Switch 1 2 3 4 5 6 9 8 10 Overload Alarm 11 Output Indicator 12 Low Oil Alarm 13 Parameter Reset Button 14 Parameter Display...

Страница 9: ...C output voltage rises above rated values The Output Indica tor Green will go off and the Overload Alarm Red will stay on but the engine will continue to run When the Overload Alarm light comes on and...

Страница 10: ...tec Service Provider according to the connected electrical load The results are better fuel consumption and less noise When the switch is in the OFF position the engine runs at 3600rpm regardless of w...

Страница 11: ...lames pilot lights heat and other ignition sources DO NOT light a cigarette or smoke when filling the fuel tank Fuel is highly FLAMMABLE and its vapours are EXPLOSIVE NOTE The battery supplied is NOT...

Страница 12: ...engine or carburetor cleaner products in the fuel tank as permanent damage may occur Remove the fuel cap turning counter clockwise Fill the tank with regular unleaded gaso line without exceeding the...

Страница 13: ...TU 3800 5000 32 000 BTU 5000 6500 Room Air Conditioner 10 000 BTU 1500 2200 Circular Saw 7 1 4 1400 2300 Chainsaw 2HP 1100 2500 Portable Air Compressor 1200 3600 Hand Drill 1 2 600 900 Drill 1 2 600 9...

Страница 14: ...e unit is in a level position Turn choke to ON position NOTE It may not be necessary to use the choke if the engine has been shut down and is warm NOTE If engine does not start up within 3 to 4 second...

Страница 15: ...ance is felt and then pull rapidly to avoid kickback Never start or stop engine with electrical devices plugged in and turned on If engine fails to start after 3 pulls or if unit shut down during oper...

Страница 16: ...top the engine with electrical devices plugged in and turned on Let engine run at no load for several minutes to stabilise the internal temperatures of engine and generator Move ON OFF switch to OFF p...

Страница 17: ...are visible on its exterior surface CAUTION Never insert any object or tool through the air cooling slots even if the engine is not running Items should be maintained and repaired by an Authorized Pow...

Страница 18: ...not operate engine in a poorly ven tilated room or other enclosed area Be sure to keep good ventilation in working area The exhaust from engine may contain poisonous CO inhalation can cause shock unc...

Страница 19: ...ke out the filter element B Clean the filter in a soap and water solu tion E Allow it to dry completely Dip the dry filter in oil F the same type as used in the generator engine Squeeze out excess oil...

Страница 20: ...he fixing screws Clean carbon deposits carefully with a brush Re install the spark arrester Transportation Storage Transportation In order to avoid fuel spillage during transportation always keep the...

Страница 21: ...ew again Remove the spark plug see page 19 for more info on removing spark plug Pour 1 tablespoon of clean motor oil 10 20ml in the cylinder Pull recoil handle gently this will mnake the engine spin a...

Страница 22: ...ct warranty serious personal injury property damage or even death If possible store the unit indoors and cover it to give protection from dust and dirt BE SURE TO EMPTY THE FUEL TANK If it is not prac...

Страница 23: ...mstances such as contaminated fuel or poor water supply modifica tions to the product attempted repair service by a party other than an Approved Service Agent is not covered under warranty Warranty do...

Страница 24: ...customer and will strive to provide you with the best service and reliability in the industry This product is backed by our extensive warranty and world wide service network Please contact your local...

Отзывы: