17
NOTE: DO NOT use a garden hose
to clean generator. Water can enter
the engine fuel system and cause
problems. In addition, if water enters
the generator though cooling air slots,
some water will be retained in voids
and crevices of the rotor and stator
winding insulation. Water and dirt build-
up on the generator internal windings
will eventually decrease the insulation
resistance of these windings.
Maintenance
Maintenance Schedule
Follow the calendar intervals shown below.
More frequent service is required when
operating in adverse conditions.
Generator Maintenance
Generator maintenance consists of keeping
the unit clean and dry. Operate and store
the unit in a clean dry environment where it
will not be exposed to excessive dust, dirt,
moisture or any corrosive vapours. Cooling
air slots in the generator must not become
clogged with debris.
• Check for any foreign materials while
changing the engine oil and report to
repair agent if necessary
• Check the cleanliness of the generator
frequently and clean when dust, dirt, oil,
moisture or other foreign substances are
visible on its exterior surface.
CAUTION! Never insert any object or
tool through the air cooling slots, even
if the engine is not running.
* Items should be maintained and repaired by an Authorized Powertec Service Supplier.
SERVICE
MAINTENANCE SCHEDULE
Engine Oil
Check the level before each use. First oil change after 20 hours of break-in.
Subsequent oil changes every 100 hours of use.
Air Filter
Check and clean every 50 hours. Replace after 250 hour or before any
damage is noticed.
Spark Plug
Check and adjust the electrode every 50 hours. Replace after 250 hours or
before any damage is noticed.
Fuel Filter
Clean every 300 hours or 12 months (whichever is first)
Spark Arrester
Clean every 300 hours or 12 months (whichever is first)
Engine Valves
Adjust every 500 hours
Combustion Chamber Clean every 500 hours*
Fuel Tank *
Clean every 500 hours*
Fuel Hose*
Replace every 2 years or sooner of any wear is noticed*
To Clean the Generator
• Use a damp cloth to wipe exterior
surfaces.
• A soft, bristle brush may be used to
remove dirt, oil etc.
• A vacuum cleaner may be used to pick up
loose dirt and debris.
• Low pressure air (not to exceed 25psi)
may be used to blow away dirt. Check
cooling air slots and openings on the
generator. These openings must be kept
clean and unobstructed.