background image

11

•   Place generator on a flat, level surface.

•   Remove oil cap and dipstick. Wipe  

  dipstick clean. 

•  Slowly fill oil into engine through the oil  

  filter until it reaches the full mark on the  

 dipstick.

•  Stop filling occasionally to check oil level.  

  Be careful to not overfill.
•   Install oil fill cap and fasten the cap  

 properly.
•   Check engine oil level before starting  

  each time thereafter.

NOTE: Never use old, dirty or bad 

oils. Do not use oil if you don’t know 

it’s grade or quality. Do not mix 

different types of oils.

Adding Fuel

DANGER! Never fill tank indoors. 

Never fill fuel tank when engine is 

running or hot. Turn generator engine 

OFF and allow engine to cool entirely 

before filling fuel tank. Avoid spilling 

gasoline on HOT engine. Keep fuel 

away from sparks, open flames, 

pilot lights, heat, and other ignition 

sources. DO NOT light a cigarette 

or smoke when filling the fuel tank. 

Fuel is highly FLAMMABLE and its 

vapours are EXPLOSIVE.

NOTE: The battery supplied is NOT 

covered under warranty. Batteries 

have limited lifespans and should be 

replaced when required by a battery 

with the same specifications.

Adding Engine Oil

Please add correct oil before starting the

generator.
Above 5

o

- use SAE 30

Between 5

o

C to -15

o

- use 10W-30

Oil Capacity - GT3800Ei - 600ml 
 

      - GT4500Ei - 1L

recommended oil. This could result in 

an engine failure.

Preparation before 
Operating

Battery Connection

The battery supplied has the negative 

terminal disconnected. Before connecting 

check that the engine switch is in the ‘OFF’ 

position. Connect the negative wire using 

the wingnut supplied.

NOTE: Improper treatment of 

generator could damage it and 

shorten its life. DO NOT attempt 

crank or start the engine before it 

has been properly serviced with the 

Содержание GT3800Ei

Страница 1: ......

Страница 2: ...Product 3 Description of Symbols 3 Specifications 3 Safety Rules 4 Unpacking the Generator 6 Features and Controls 7 Control Functions 9 Preparation Before Operating 11 Calculating Your Power Needs 1...

Страница 3: ...orted taken to the local recycling centre and disposed of in an environmentally safe way Scope Of Product This product is suited for home and camping back up power rural and commercial applications De...

Страница 4: ...xhaust gas away from entering a confined area through windows doors ventilation intakes or other openings NEVER operate this product inside any building carport porch mobile equipment marine applicati...

Страница 5: ...fault circuit interrupter in any damp or highly conductive area such as metal decking or steel work DO NOT touch bare wires or receptacles DO NOT use generator with electrical cords which are worn fra...

Страница 6: ...e caught in the starter or other rotating parts Tie up long hair and remove jewellery DO NOT modify generator in any way NOTE Exceeding generators wattage amperage capacity could damage generator and...

Страница 7: ...strations with your generator to familiarise yourself with the locations of various controls and adjustments Save this manual for future reference 1 Fuel Cap 2 Fuel Level Indicator 3 Fuel Tank 4 Carry...

Страница 8: ...AC Breaker 6 2 x USB Ports 7 Ground Terminal 8 Eco Mode Switch 9 Start Stop Switch 1 2 3 4 5 6 9 8 10 Overload Alarm 11 Output Indicator 12 Low Oil Alarm 13 Parameter Reset Button 14 Parameter Display...

Страница 9: ...C output voltage rises above rated values The Output Indica tor Green will go off and the Overload Alarm Red will stay on but the engine will continue to run When the Overload Alarm light comes on and...

Страница 10: ...tec Service Provider according to the connected electrical load The results are better fuel consumption and less noise When the switch is in the OFF position the engine runs at 3600rpm regardless of w...

Страница 11: ...lames pilot lights heat and other ignition sources DO NOT light a cigarette or smoke when filling the fuel tank Fuel is highly FLAMMABLE and its vapours are EXPLOSIVE NOTE The battery supplied is NOT...

Страница 12: ...engine or carburetor cleaner products in the fuel tank as permanent damage may occur Remove the fuel cap turning counter clockwise Fill the tank with regular unleaded gaso line without exceeding the...

Страница 13: ...TU 3800 5000 32 000 BTU 5000 6500 Room Air Conditioner 10 000 BTU 1500 2200 Circular Saw 7 1 4 1400 2300 Chainsaw 2HP 1100 2500 Portable Air Compressor 1200 3600 Hand Drill 1 2 600 900 Drill 1 2 600 9...

Страница 14: ...e unit is in a level position Turn choke to ON position NOTE It may not be necessary to use the choke if the engine has been shut down and is warm NOTE If engine does not start up within 3 to 4 second...

Страница 15: ...ance is felt and then pull rapidly to avoid kickback Never start or stop engine with electrical devices plugged in and turned on If engine fails to start after 3 pulls or if unit shut down during oper...

Страница 16: ...top the engine with electrical devices plugged in and turned on Let engine run at no load for several minutes to stabilise the internal temperatures of engine and generator Move ON OFF switch to OFF p...

Страница 17: ...are visible on its exterior surface CAUTION Never insert any object or tool through the air cooling slots even if the engine is not running Items should be maintained and repaired by an Authorized Pow...

Страница 18: ...not operate engine in a poorly ven tilated room or other enclosed area Be sure to keep good ventilation in working area The exhaust from engine may contain poisonous CO inhalation can cause shock unc...

Страница 19: ...ke out the filter element B Clean the filter in a soap and water solu tion E Allow it to dry completely Dip the dry filter in oil F the same type as used in the generator engine Squeeze out excess oil...

Страница 20: ...he fixing screws Clean carbon deposits carefully with a brush Re install the spark arrester Transportation Storage Transportation In order to avoid fuel spillage during transportation always keep the...

Страница 21: ...ew again Remove the spark plug see page 19 for more info on removing spark plug Pour 1 tablespoon of clean motor oil 10 20ml in the cylinder Pull recoil handle gently this will mnake the engine spin a...

Страница 22: ...ct warranty serious personal injury property damage or even death If possible store the unit indoors and cover it to give protection from dust and dirt BE SURE TO EMPTY THE FUEL TANK If it is not prac...

Страница 23: ...mstances such as contaminated fuel or poor water supply modifica tions to the product attempted repair service by a party other than an Approved Service Agent is not covered under warranty Warranty do...

Страница 24: ...customer and will strive to provide you with the best service and reliability in the industry This product is backed by our extensive warranty and world wide service network Please contact your local...

Отзывы: