7.2 SMS Commands for Arm or Disarm or Inquiry system status or switch on/off independent output relay.
The User can Arm/Disarm/Inquriysystem status/Switch on or off the independent output relay by sending SMS to
the Control unit. The SMS Commands are below:
Notice:
The system will carry out the commands immediately (with no delay) after the Control Unit receive this SMS command.
7.2.1 Armed
7.2.2 Disarm
7.2.3 Switch On the independent output relay
7.2.4 Switch OFF the independent output relay
7.2.5 Inquiry System Status
Notice:
xxxxEE
“xxxx” stands for the password (1-4 digits).
Return SMS
Armed or At House or Disarmed
AC Power is Ok or AC Power is failed
GSM Value is 17
or other value
Output Relay is Closed or
Output Relay is opened
Example
1111DD
When the Password is 1111
xxxxDD
“xxxx” stands for the password
(1-4 digits).
Return SMS
Output Relay Opened.
Example
1111CC
When the Password is 1111
xxxxCC
“xxxx” stands for the password
(1-4 digits).
Return SMS
Output Relay Closed.
xxxxAA
“xxxx” stands for the password
(1-4 digits).
Return SMS
All Armed Mode activated.
Example
1234AA
When the Password is 1234
Example
1111BB
When the Password is 1111
xxxxBB
“xxxx” stands for the password
(1-4 digits).
Return SMS
System deactivated.