19
of 23 Ver 2.0 File No.: S1200020
A Professional GSM Alarm System designer and manufacturer!
GSM SMS Controller Alarm &GSM House Alarm System&
GSM Telemetry Units & GSM GPRS Logging System
8.6
Install Siren
Connect the Siren to the Control Unit and fix them in appropriate locations.
If you need soundly siren or need the
siren to sound continuous 4 minutes, please contact the siren to the Relay Output 1, the connection please
reference Diagram 3. Please note the rated voltage is different for siren and lights.
Tips!
The Siren should be at least 1.5meters away from the GSM SMS Controller unit, if possible, more than 3meters is better.
Siren Strobe Siren
9. Add Wireless Detectors to the Control Unit
Notice:
Some wireless detectors must be coded by manual as below 9.1 step; some wireless detectors needn’t coded by manual,
because of we will use the learning code detector. The learning code wireless detector you can omit the 9.1 step, can be learned
to the system directly, like the PIR-100B and DM-100A.
The Wireless detectors in the package box are pre-coded prior to shipping. The Max. Quantity of RF detectors is
16, if you need add more then you can set the wireless detector with the same jumper. Add additional wireless
detectors to the control units, please help to see below:
9.1 Prepare the RF Detectors of PT2262 IC Code
1) Prepare the RF detectors, Open the back cover of the Wireless detector carefully;
2) Locate the IC boards black jumpers, labeled A0-A7 and D0-D3.
3) Configured the A0~A7 and D0~D3 different from each wireless detectors(Includes wireless door detector,
wireless smoke detector, wireless gas leakage detector, wireless pir motion detector and so on). If configured
the A0~A7 and D0~D3 are the same, the system will treat them as the same one detector.
4) Also, please check the Resistors value is 3.3M Ohm, there’re 3 Jumpers, 1.5M,3.3M, and 4.7M. if you select
incorrect value, the wireless distance usually very short or can not learn to the alarm panel.
9.2 Enter the RF Detector Adding Menu.(See 6.2.2.1 Add/Del RF Parts)
Select the Zone number, press Ok, finished it then press OK to select the Normal Type Or Stay Type, then
following the instruction:
1.Turn On the Device
, means trigger the RF detector, the system will show a code, then
press Enter Key
on the Keyboard. The system will ask you repeat the operation, so please trigger RF detector
again, when you see the Code, then press the Enter Button on the Keyboard, the system will display
Saved OK
. It
means the wireless detector added to the system. Repeat this operation to add other wireless detectors.
Notice:
a) One time can add only 1 wireless detector;
b) The Name of the RF detector can be modified by SMS commands. Please see chapter 6.3.