17
of 23 Ver 2.0 File No.: S1200020
A Professional GSM Alarm System designer and manufacturer!
GSM SMS Controller Alarm &GSM House Alarm System&
GSM Telemetry Units & GSM GPRS Logging System
Wireless curtain detector, detection area illustration below:
8.4 Install the Wired Detectors and Electricity equipments
Please help to see below wiring diagram, then fixed the related wired detectors, the detectors connect to the
related digital inputs.
Tips!
1) Please setup the NC, NO, EOL type in the LCD Menu correctly;
2) If you setup the Nodes type as NC, and the detector type must be NC. Please see below diagram.
3) If you setup the input type as EOL, then please contact a 2.2K Resistor in series for NC type detector, and contact a 2.2K
Resistor in parallel for NO type Detector. Please see the below diagram.
4) If you setup the input type as NO, the detector type must be NO. Please see the below diagram.
5) The Unit built-in 240VAC@3A rated relay. Please make sure the power cord rated while you connect to equipment device. also,
please make sure the power consumption is less than 250W for long time working. If you need heavy equipment, please
connect an additional relay ;
6) The R1+ and R1- is for alarm-link output, when the system alarm, will close for 4 minutes, the rated output power is 700W. If you
need heavily equipment, please connect an additional relay .
7) The R2+ and R2- is the relay output for SMS Command, CC is close, DD is open, EE is inquiry the status.
8) The +12VDC is for the Detectors, if the detectors need 12VDC power, then please contact it to the +12VDC. The 12VDC power
is from external power, not from backup battery. So please note: When AC power failure, the +12VDC point will no power
supply.
Diagram 1