20
of 23 Ver 2.0 File No.: S1200020
A Professional GSM Alarm System designer and manufacturer!
GSM SMS Controller Alarm &GSM House Alarm System&
GSM Telemetry Units & GSM GPRS Logging System
9.3 Add Remote keys to the Control unit:
Because of both of the S120 and its remote keys are with learning code, you can add the remote keyto the S120
directly following the 6.2.2.1 Add/Del RF Parts
a) Enter the Add/Del RF Parts menu;
b) Select 2. Edit Remote Ctrl
, then press
Enter
button,
c)
then following the instruction:
1.Turn On the Device
, means trigger the Remote Control, the system will show
a code, then
press Enter Key
on the Keyboard. The system will ask you repeat the operation, so please
trigger Remote keyagain, when you see the Code, then press the Enter Button on the Keyboard, the system
will display
Saved OK
. It means the Remote keyadded to the system. Repeat this operation to add other
remote keys.
Notice:
1) VVVV means this serial position saved one remote keyalready; you can learn a new remote keyto replace it.
9.4 Delete all wireless detectors and remote keys.
Go back to the menu, then select the Remove All, select it then the system will alert
Are You Sure
Æ
Press Enter
to remove all the RF Parts of the system.
10. Technical specifications of Control Unit
Rated Voltage: 12VDC 2A
Siren Output Voltage:
12VDC
Working temperature: -10
℃~
+60
℃
; Storage temperature:-20
℃~
+60
℃
Relative humidity: 10-90%, No condensation
Work frequency: 850/900/1800/1900MHz
Communication protocol: GSM PHASE 2/2+ (include data service)
Wireless detector receiving frequency: 433.92 MHz
Wireless Zone: 16 (Accept Max.16Pcs Learning Code Detectors, Unlimited of fixed code Detectors )
Wired Zones: 20, Dry Contact, NC,NO,EOL.
Remote key permission quantity: 5Pcs
Effective distance wireless of remote control: 100 m in open air.
Backup Battery: 3Pcs, Rechargeable lithium battery: 1.2Ah@12V
Standby time Approx.18hours (depending on the network condition)
Dimensions: 225mmX160mmX50mm (WXDXH); Net Weight: approx. 1.00Kg.
11. Important information
1) When the AC power failure, the +12V for wired detector’ power is from the backup battery, so please don’t
connect heavy detector to it.
2) Please read the User Manual carefully before you install the Control Unit and set the Control Unit.
3) Do not install the system in close vicinity with objects that generate strong interference, such as TV set and
computer.
4) Install the system in a hidden place.
5) Avoid getting water into the Control Unit.
6) Have a secure connection to the main power supply.
7) This product was designed for the indoor use.
8) Opening the control unit cover will avoid the warranty.