4. Product description
4.1 Selcoperm electrolysis system (SES)
4.1.1 Intended use
The Selcoperm electrolysis system is a modular system for the
safe production of a 0.8 % sodium hypochlorite solution from a
diluted brine solution. The system is suitable for the disinfection
of drinking water and industrial process water. The intended use
of the Selcoperm system comprises the stationary operation
either in continuous or batch processing.
Typical disinfection applications for Selcoperm systems are:
• drinking water treatment,
• water treatment for industrial processes and cooling towers.
4.1.2 Improper use
Applications other than those described in section
are not in accordance with the intended use and are not
permitted. The manufacturer, Grundfos, accepts no liability for
any damage resulting from incorrect use.
• The system must not be used if it is damaged.
• The system must not be used after improper repair.
• The system must not be used after unauthorised modification.
• The system must not be used in potentially explosive areas.
4.1.3 Safety and monitoring equipment
The Selcoperm electrolysis system is fitted with the following
safety and monitoring equipment:
• Emergency stop on the electrolyser control cabinet. Further
emergency stops can be installed on components or in the
room, if necessary.
• Leakage detection
• Transparent cover on electrolysis chamber
• Flow sensors, level sensor and temperature sensors
• Signal connection for gas warning system (H
2
)
• Ventilation system with flow sensor for safe hydrogen removal.
Unauthorised structural modifications to the system
may result in serious personal injury and damage to
equipment.
It is forbidden to dismantle, modify, change the
structure of, bridge, remove, bypass or disable
components, including safety equipment.