4.11.1 Components
Fig. 16
Acid cleaning station
4.12 Gas warning system
As a part of the safety concept, a gas warning system for
hydrogen gas (H
2
) must be installed at the installation location.
The Selcoperm electrolyser provides a two-channel safety input
to shut down the whole system in case of gas leakage.
5. Technical data
5.1 Selcoperm Electrolysis System (SES)
The following data apply to the core components of the
Selcoperm electrolysis system and cover all capacity levels.
5.1.1 Water quality specification
Make sure that the water supply conforms to the required
standard of drinking water given in the specification below. Ask
your local water supplier for the specific values.
5.1.2 Salt specification
Use food-grade granular/pellet salt (98.5 % NaCl) according to
EN 14805 type 2 with following minimum requirements:
5.1.3 Ambient conditions
* System must be drained. For storage temperatures below +5
°C, the whole system including water softener, lines and
external components must not contain any water.
T
M
06
22
26
22
16
Pos. Description
1
Collecting tray
2
Trolley
3
Acid tank, 300 l
4
Return flow line
5
Special plug for connection to Selcoperm electrolyser
6
3-way ball valve
7
Dosing pump
8
Connection to Selcoperm electrolyser with manual valve
9
3-way ball valve
10 Drain valve
11
Pressure loading valve
The values stated in the technical data must be
adhered to.
Parameters
Value (maximum unless stated
otherwise)
Colour
[mg/l Pt/Co] 20
pH value
6.5 - 10.0
Iron Fe
[
μ
g/l]
200
Manganese Mn
[
μ
g/l]
20
Fluoride F
[mg/l]
2
Turbidity
[NTU]
4
Max. particle size
[
μ
m]
100
3
4
11
2
1
9
10
8
7
6
5
Parameter
Symbol
Max. mass fraction
for dry salt [mg/kg]
Iron
Fe
10.0
Manganese
Mn
10.0
Bromide
Br
100.0
Calcium
Ca
100.0
Magnesium
Mg
100.0
Permissible ambient temperatures (min./max.)
Transport*
-10 / +50 °C
Storage*
+0 / +40 °C
Operation
+5 / +40 °C
Operation (rectifier)
+10 / +40 °C
Max. relative humidity (non-condensing)
90 %
Max. relative humidity (non-condensing) for
rectifier
75 %
Max. altitude above sea level
2000 m
Exposition to direct sunlight can cause colour
changes, material deformations and cracks.
Do not expose the system to direct sunlight.
Because of the embrittlement of plastics at low
temperatures, the transport must not be done if the
temperature falls below the specified value for
transport, otherwise plastic parts can be damaged.
Freezing and boiling liquids can cause damage.
Observe the freezing and boiling points of the used
liquids. The freezing and boiling point of a liquid
varies depending on the pressure.