English (GB)
20
4.2.6 Signal diagram
Fig. 12
Signal diagram
TM
06 221
7 361
5
t
c
a
t
n
o
c
e
e
r
f
l
a
i
t
n
e
t
o
P
Alarm 2xNC
S
e
lc
o
p
e
rm
S
E
S
-500
0 -
450
00
Con
tr
o
l Ca
bi
n
e
t
B
rin
e
do
si
ng
s
ta
Ɵ
on
DP
0
.1
0
DP
0
.1
1
Re
c
ƟĮ
er
Ac
id
cl
e
a
n
in
g
st
a
Ɵ
on
AAH
5.0
0
G
as w
a
rn
in
g sy
st
e
m
c
o
n
tr
o
lle
r
Ma
in
co
n
tr
o
l
De
g
a
ss
in
g
a
n
d
s
to
ra
g
e
t
a
n
k
EF 4.01
Ven
Ɵů
a
Ɵ
on Fan
Duty
EF 4.02
Ven
Ɵů
a
Ɵ
on Fan
Standby
FIAHL 4.13
Exhaust air
Ň
ow
sensor
LSAHH 4.12
Degassing tank
over
Ň
ow switch
4-20mA
Flow rate signal
LISAHL 4.10
Degassing tank
level senso r
LSAL 4.04
NaClO solu
Ɵ
on
line level switch
4-20mA
Tank level
Namur
Level switch
LSAH 4.03
Level switch in
reten
Ɵ
on
Poten
Ɵ
al free contact
Leakage fault signal NC
24V DC
Power Supply
14V DC
Power Supply
24V DC
Power Supply
Selcoperm electroyser
L
S
A
H
0
.01
L
e
v
e
l s
w
it
c
h
in
co
lle
c
Ɵ
ng
t
ra
y
FI
A
H
L 0
.0
2
Wa
te
r i
n
le
t
Ň
ow
se
n
so
r
24
V
D
C
P
o
we
r s
u
p
p
ly
Po
te
n
Ɵ
al
f
re
e
c
o
n
tac
t
Le
ak
ag
e
f
a
u
lt
si
g
n
al
N
C
TI
A
H
L 0
.0
3
Na
C
lO
o
u
tl
e
t
te
m
p
er
a
tu
re s
e
n
so
r
SV
0
.0
5
Wa
te
r i
n
le
t
so
le
n
o
id
v
a
lv
e
TC
T
e
m
p
er
a
tu
re s
ig
n
a
l
24
V
D
C
Po
w
e
r s
u
p
p
ly
*
TI
A
H
1
.0
1
-x
.0
4
T
e
m
p
er
a
tu
re
se
n
so
r (
D
C
+
/-
)
LS
A
L
x
.0
9
Ce
ll o
u
tle
t le
v
e
l
sw
itc
h
Le
v
e
l s
w
it
ch
FI
A
H
L x
.1
0
Ce
ll in
le
t
Ň
ow
se
n
so
r
24
V
D
C
Po
w
e
r S
u
p
p
ly
TI
A
H
L 1
.1
1
Ce
ll in
le
t
te
m
p
er
a
tu
re s
e
n
so
r
3 PE
Power supply*
24V DC
Power Supply
4-20mA
Flow rate
230V AC
Power supply*
Poten
Ɵ
al free contact
Fault signal
Pro
Į
net
Current, Voltage, ...
230V AC
Power supply*
4-20mA
Flow rate
230V AC
Power supply*
Poten
Ɵ
al free contact
Fault signal
Poten
Ɵ
al free contact
Emergency stop 2xNC
Poten
Ɵ
al free contact
Emergency stop 2xNC
Watch dog
380/400/415V AC 50/60Hz (3 N +PE)
Power supply BY COSTUMER
GSM OPTIONAL
Remote maintenance by GRUNDFOS
Pr
o
Į
ne
t
2.
)
Po
te
n
Ɵ
al
f
re
e
c
o
n
tac
t
Em
e
rg
e
n
cy
s
to
p
2
x
N
C
Po
te
n
Ɵ
al
f
re
e
c
o
n
tac
t
Em
e
rg
e
n
cy
s
to
p
2
x
N
C
2.
) S
ign
a
ls
(P
o
te
n
Ɵ
al
f
re
e
o
r P
ro
Į
ne
t)
- St
a
n
d
b
y
- Ru
n
- Fa
u
lt
- W
a
te
r
re
q
u
e
st
- R
e
le
a
se
N
a
C
lO
dos
ing
pum
p
- R
e
le
ase
N
a
C
lO
tr
an
s
fe
r p
u
m
p
5V D
C
Po
w
e
r s
u
p
p
ly
0,
5-
3,
5
V
D
C
Fl
o
w
r
a
te
s
ig
n
a
l
5V D
C
P
o
we
r s
u
p
p
ly
0,
5-
3,
5
V
D
C
Fl
o
w
r
a
te
s
ig
n
a
l
5V
D
C
Po
w
e
r s
u
p
p
ly
0,5-
3,
5
V
D
C
Fl
o
w
r
a
te
s
ig
n
a
l
Po
te
n
Ɵ
al
f
re
e
c
o
n
tac
t
Re
m
o
te
o
n
/o
ī
Po
te
n
Ɵ
al
f
re
e
c
o
n
tac
t
2.
)
Al
a
rm
2
x
N
C
TC
Te
m
p
e
ra
tu
re
s
ig
n
a
l
Namur
Level switch
14V DC
Power Supply
Po
te
n
Ɵ
al
f
re
e
c
o
n
tac
t
Em
e
rg
e
n
cy
s
to
p
2
x
N
C
E
t
2
N
C
38
0
/40
0
/41
5
V
A
C
3
p
h
a
se
s +
P
E
, 50
H
z
Po
w
e
r s
u
p
p
ly
B
Y
C
O
S
T
U
M
E
R
P
P
l
l
l
B
B
Y
Y
C
C
O
O
S
S
T
T
U
U
M
M
E
E
R
R
A5.
0
1
Hy
d
ro
g
e
n
(
H
2
)
se
n
so
r 1
A5.
0
2
Hy
d
ro
g
e
n
(
H
2
)
se
n
so
r 2
*
pe
rm
a
n
e
n
t p
o
we
r
su
p
p
ly
E
m
e
rg
e
nc
y
s
top
d
o
e
s
no
t l
e
a
d
t
o
d
e
-e
ne
rg
is
e
d
c
o
mp
on
e
n
t
Poten
Ɵ
al free contact
Start / Sto p
Poten
Ɵ
al free contact
Fault signal
3 PE
Power supply*
Poten
Ɵ
al free contact
Start / Sto p
Poten
Ɵ
al free contact
Fault signal
Po
te
n
Ɵ
al
f
re
e
c
o
n
tac
t
E
x
te
rn
al
al
ar
m
i
n
p
u
t