English (GB)
16
Fig. 9
Overview components SES-20000 to SES-45000
TM
06
46
71
51
15
1
2
2
3
4
11
5
6
Z
A
B
V
V
6
6
Pos. Description
1
Chemically resistant PEHD frame with collecting tray
2
Easily removable powder-coated housing
3
Horizontal electrolysis cells with transparent PVC pipe for easy process monitoring and visual electrode check. Several sensors
monitor the level and temperature of the liquid as well as the voltage and temperature of all direct-current (DC) connections.
4
Lockable hydraulic chamber with shut-off valves and adjusting valves, temperature sensors, flow sensors and leakage sensors,
sample valves for brine and sodium hypochlorite solution, and a connection for acid cleaning.
5
Lockable control cabinet with multi-colour touchscreen, emergency stop and main switch. The control cabinet monitors and/or
controls the following components and functions:
• Rectifier
• Brine dosing station
• Sensors and valves of the Selcoperm electrolyser
• Level sensors and flow sensors of the degassing and storage tank and the sodium hypochlorite solution line
• Degassing fans (duty/standby) of the degassing and storage tank
• Potential-free contact for start signal of dosing pumps or transfer pumps downstream the degassing and storage tank
• Gas warning system
• Several potential-free alarm contacts
• Acid cleaning station
• Remote maintenance (optional)
6
Top or bottom connection for direct current cables from the rectifier
11
7" multi-colour touchscreen for operating and monitoring of the whole electrolysis system. Several languages can be selected.
The system can be operated in two operation modes:
• automatic mode
• service mode
The system can also be remotely controlled and monitored via PROFINET.
A
Soft water inlet
B
Brine inlet
V
NaClO solution outlet
Z
Drain outlet